:208 mW (24 V DC)
EMC:A
Note:When being exposed to interference, there may be minimal deviations.
Color:green (RAL 6021)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
208 mW (24 V DC)
EMCA
NoteWhen being exposed to interference, there may be minimal deviations.
Colorgreen (RAL 6021)
Depth101.2 mm
Width6.2 mm
Height93.1 mm
Ripple< 20 mVrms(at 500 Ω)
Altitude≤ 2000 m
CommentsSafety measures must be taken to prevent electrostatic discharge.
EMC noteEMC: class A product, see manufacturer's declaration in the download area
HumidityB
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationB
InsulationBasic insulation in accordance with IEC/EN 61010
CertificateCE-compliant
DesignationElectromagnetic RF field
TemperatureB
Product typeRepeater power supply
Screw threadM3
Test voltage1.5 kV AC (50 Hz, 60 s)
Assembly noteThe DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715.
Mounting typeDIN rail mounting
IdentificationUL 508 Recognized
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Product familyMINI Analog
No. of channels1
Article revision16
Housing materialPBT
Non-load voltageapprox. 12.5 V
Number of inputs1
Pollution degree2
Stripping length12 mm
Connection methodScrew connection
Mounting positionany
Number of outputs1
Power consumption< 900 mW (at 24 V DC and in repeater power supply operation)
Protective circuitTransient protection
Dimensional drawing
Current input signal0 mA ... 20 mA (isolator operation)
Degree of protectionIP20
Electrical isolation3-way isolation
Overvoltage categoryII
Supply voltage range19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Current output signal0 mA ... 20 mA (isolator operation)
Standards/regulationsEN 61000-4-2
Limit frequency (3 dB)approx. 100 Hz
Nominal supply voltage24 V DC
Step response (10-90%) 3.5 ms
Description of the inputSensor circuit
Rated insulation voltage50 V AC/DC
Max. current input signal28 mA
Max. current output signal28 mA
Maximum transmission error≤ 0.2 % (of final value)
Transmitter supply voltageUB- max. 4.5 V for load 0 mA ... 20 mA
Conductor cross section AWG26 ... 12
Transmission error, typical≤ 0.1 % (of final value)
Signal transmission behaviorIn = Out
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Electromagnetic compatibilityConformance with EMC directive
Input resistance current inputapprox. 50 Ω
Ambient temperature (operation)-20 °C ... 60 °C
Load/output load current output≤ 500 Ω (I = 20 mA)
Maximum temperature coefficient< 0.01 %/K
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Temperature coefficient, typical< 0.002 %/K
Transmitter supply voltage range14.7 V DC ... 25.5 V DC
Ambient temperature (storage/transport)-40 °C ... 85 °C
Electrical isolation between input and outputyes
Maximum power dissipation for nominal condition508 mW (24 V DC)
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2
Typical deviation from the measuring range final value10 %

Product Description

MCR feeder separator, with screw connection, input signal: (0)4..20 mA, output signal: (0)4..20 mA
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top