Key Specifications
GTIN:4046356046466
Orderkey:2864202
(EMC data):Class I, Div. 2, Groups A, B, C, D T5
Catalog page:Page 104 (C-7-2015)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356046466
Orderkey2864202
(EMC data)Class I, Div. 2, Groups A, B, C, D T5
Catalog pagePage 104 (C-7-2015)
Packing unit1 pc
(Input data)< 20 mVPP(at 10 kΩ)
GL (EMC data)GL EMC 2 D
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Div. 2, Groups A, B, C, D T5
Ripple (Input data)< 20 mVPP(at 500 Ω)
Custom tariff number85437090
GL (Connection data)GL EMC 2 D
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant
Designation (EMC data)Conducted interferences
Color (Connection data)green
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 508 Recognized
Depth (Key Commercial Data)102.5 mm
Width (Key Commercial Data)6.2 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)93.1 mm
Conformance (Connection data)CE-compliant
Number of outputs (Input data)1
Electrical isolation (EMC data)Basic insulation according to EN 61010
Power consumption (Output data)< 500 mW
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)8 mm
Connection method (Power supply)Spring-cage connection
Max. output current (Input data)23 mA
Max. output voltage (Input data)approx. 12.5 V
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Standards/regulations (EMC data)EN 61000-4-6
UL, USA/Canada (Connection data)UL 508 Recognized
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PBT
Short-circuit current (Input data)approx. 10 mA
Supply voltage range (Output data)19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Voltage output signal (Input data)0 V ... 10 V
Mounting position (Connection data)any
Nominal supply voltage (Output data)24 V DC
Protective circuit (Connection data)Transient protection
Weight per Piece (excluding packing)59.900 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)Basic insulation according to EN 61010
Max. current consumption (Output data)< 21 mA (at 24 V DC)
Overvoltage category (Connection data)II
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Sensor input current (Ambient conditions)1 mA (constant)
Connection technology (Ambient conditions)2, 3, 4-wire
Rated insulation voltage (Connection data)50 V AC/DC
Connection in acc. with standard (EMC data)CUL
Ambient temperature (operation) (Dimensions)-20 °C ... 65 °C
Load/output load current output (Input data)< 500 Ω (at 20 mA)
Load/output load voltage output (Input data)> 10 kΩ
Conductor cross section AWG max. (Power supply)12
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-50 °C ... 200 °C
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)< 0.02 %/K
Test voltage, input/output/supply (Connection data)1.5 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types (RTD) that can be used (Ambient conditions)Pt 100 (IEC 60751/EN 60751)
Transmission error in the set measuring range (Connection data)((50 K / Δ Temp)+ 0.05)%
Transmission error in the full measuring range (Connection data)≤ 0,25 %
Typical deviation from the measuring range final value (General)10 %
Fire protection for rail vehicles (DIN EN 45545-2) R22 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty