| Parameter | Value |
|---|---|
| 1 V ... 5 V | |
| EMC | A |
| Note | When being exposed to interference, there may be minimal deviations. |
| Color | green (RAL 6021) |
| Depth | 101.2 mm |
| Width | 6.2 mm |
| Height | 93.1 mm |
| Ripple | < 20 mVPP(at 500 Ω) |
| Altitude | ≤ 2000 m |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Humidity | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Vibration | B |
| Insulation | Basic insulation in accordance with IEC/EN 61010 |
| Certificate | CE-compliant |
| Designation | Electromagnetic RF field |
| Temperature | B |
| Product type | Temperature transmitter |
| Screw thread | M3 |
| Sensor type: | -50 °C ... 200 °C (configurable) |
| Test voltage | 1.5 kV AC (50 Hz, 60 s) |
| Configuration | DIP switches |
| Mounting type | DIN rail mounting |
| Identification | UL 508 Recognized |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Product family | MINI Analog |
| Article revision | 12 |
| Housing material | PBT |
| Non-load voltage | 12.5 V |
| Number of inputs | 1 |
| Pollution degree | 2 |
| Stripping length | 12 mm |
| Connection method | Screw connection |
| Mounting position | any |
| Number of outputs | 1 |
| Power consumption | < 500 mW |
| Protective circuit | Transient protection |
| Dimensional drawing | |
| Degree of protection | IP20 |
| Overvoltage category | II |
| Sensor input current | 1 mA (constant) |
| Supply voltage range | 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Connection technology | 2-, 3-, 4-conductor |
| Current output signal | 0 mA ... 20 mA |
| Short-circuit current | 10 mA |
| Standards/regulations | EN 61000-4-2 |
| Voltage output signal | 0 V ... 5 V |
| Nominal supply voltage | 24 V DC |
| Step response (0–99%) | < 200 ms |
| Max. current consumption | < 21 mA (at 24 V DC) |
| Rated insulation voltage | 50 V AC/DC |
| Configurable/programmable | Yes |
| Max. current output signal | 23 mA |
| Max. voltage output signal | 12.5 V |
| Conductor cross section AWG | 26 ... 12 |
| Temperature measuring range | min. 50 K |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Electromagnetic compatibility | Conformance with EMC directive |
| Ambient temperature (operation) | -20 °C ... 65 °C |
| Load/output load current output | < 500 Ω (at 20 mA) |
| Load/output load voltage output | > 10 kΩ |
| Maximum temperature coefficient | < 0.02 %/K |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Sensor types (RTD) that can be used | Pt 100 (IEC 60751/EN 60751) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible overall conductor resistance | 10 Ω (Per cable) |
| Transmission error in the set measuring range | ((50 K / Δ Temp)+ 0.05)% |
| Transmission error in the full measuring range | ≤ 0.25 % |
| Maximum power dissipation for nominal condition | 235.5 mW |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Typical deviation from the measuring range final value | 10 % |
Technical specifications and performance data
Installation and operation guide