Service time: Monday to Friday 9:00-18:00
MINI MCR-SL-IDS-I-I - MINI MCR-SL-IDS-I-I 2905577 PHOENIX CONTACT Output signal conditioner
In Stock Hot Product

MINI MCR-SL-IDS-I-I

MINI MCR-SL-IDS-I-I 2905577 PHOENIX CONTACT Output signal conditioner

$0.00USD
4291 in stock
Key Specifications
GTIN:4046356966290
Note:Made to Order (non-returnable)
Orderkey:2905577
(EMC data):Class I, Zone 2, Group IIC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356966290
NoteMade to Order (non-returnable)
Orderkey2905577
(EMC data)Class I, Zone 2, Group IIC
Catalog pagePage 100 (C-7-2015)
Depth (Note)102.5 mm
Packing unit1 pc
Width (Note)6.2 mm
(Input data)0 mA ... 20 mA
GL (EMC data)GL applied for
Height (Note)93.1 mm
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC
Ripple (Input data)< 20 mVrms
Custom tariff number85437090
GL (Connection data)GL applied for
(Ambient conditions)0 mA ... 20 mA
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant
Designation (EMC data)Conducted interferences
Color (Connection data)green
Output name (Input data)Current output
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 508 Listed
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Number of outputs (Input data)1
Electrical isolation (EMC data)Basic insulation according to EN 61010
Power consumption (Output data)< 600 mW (at 24 V DC)
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)12 mm
Connection method (Power supply)Screw connection
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Standards/regulations (EMC data)EN 61000-4-6
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)1
Current output signal (Input data)4 mA ... 20 mA
Housing material (Connection data)PBT
Supply voltage range (Output data)19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Transmission Behavior (Input data)1:1 to input signal
Mounting position (Connection data)any
Nominal supply voltage (Output data)24 V DC
Protective circuit (Connection data)Transient protection
Weight per Piece (excluding packing)87.700 g
Degree of pollution (Connection data)2
Number of inputs (Ambient conditions)1
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)Basic insulation according to EN 61010
Overvoltage category (Connection data)II
Assembly instructions (Connection data)To bridge the supply voltage, the DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used. It can be snapped onto a 35 mm DIN rail according to EN 60715.
Max. input current (Ambient conditions)20 mA
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Limit frequency (3 dB) (Connection data)> 175 Hz
Step response (10-90%) (Connection data)< 2 ms
Current input signal (Ambient conditions)4 mA ... 20 mA
Rated insulation voltage (Connection data)50 V AC/DC
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C
Load/output load current output (Input data)≤ 800 Ω (at 20 mA)
Maximum transmission error (Connection data)≤ 0.1 % (of final value)
Input voltage limitation (Ambient conditions)< 2 V (20 mA)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Conductor cross section AWG max. (Power supply)12
Conductor cross section AWG min. (Power supply)26
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)< 0.01 %/K
Temperature coefficient, typical (Connection data)< 0.01 %/K
Test voltage, input/output/supply (Connection data)1.5 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Typical deviation from the measuring range final value (General)3 %
Fire protection for rail vehicles (DIN EN 45545-2) R22 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2

Product Description

3-way output splitter amplifiers for 0/4 ... 20 mA signals from the control system for a load that is in the field simultaneously with 3-way separation between input, output and screw connection suppl
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top