Service time: Monday to Friday 9:00-18:00
MINI MCR-SL-FM-RC-NC - MINI MCR-SL-FM-RC-NC 2902961 PHOENIX CONTACT Monitoring module
In Stock Hot Product

MINI MCR-SL-FM-RC-NC

MINI MCR-SL-FM-RC-NC 2902961 PHOENIX CONTACT Monitoring module

$0.00USD
3339 in stock
Key Specifications
GTIN:4046356702850
Note:Made to Order (non-returnable)
Orderkey:2902961
(General):Class I, Zone 2, Group IIC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356702850
NoteMade to Order (non-returnable)
Orderkey2902961
(General)Class I, Zone 2, Group IIC
Catalog pagePage 524 (C-5-2017)
Depth (Note)102.5 mm
Packing unit1 pc
Width (Note)6.2 mm
Height (Note)93.1 mm
ATEX (General) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC
Comments (General)Criterion B
Custom tariff number85369010
Conformance (General)CE-compliant
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Color (Connection data)green
Noise emission (General)EN 61000-6-4
UL, USA/Canada (General)UL 508 Listed
Output name (Output data)Switching output
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Electrical isolation (General)Basic insulation according to EN 61010
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)12 mm
Connection method (Power supply)Screw connection
Max. output current (Input data)2 A
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Status display (Connection data)Yellow LED (switching output active), red LED (error)
UL, USA/Canada (Connection data)UL 508 Listed
Housing material (Connection data)PBT
Voltage output signal (Input data)8.8 V DC ... 29.2 V DC
Max. switching current (Output data)50 mA
Power consumption (Switching output)< 120 mW (at 24 V DC)
Weight per Piece (excluding packing)81.700 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)Basic insulation according to EN 61010
Overvoltage category (Connection data)II
Electromagnetic compatibility (General)Conformance with EMC directive
Maximum switching voltage (Output data)30 V AC/DC
Supply voltage range (Switching output)9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Voltage input signal (Ambient conditions)9.6 V DC ... 30 V DC
Rated insulation voltage (Connection data)50 V AC/DC
Max. current consumption (Switching output)< 5 mA (at 24 V DC)
Test voltage input/output (Connection data)1.5 kV AC (50 Hz, 1 min.)
Ambient temperature (operation) (Dimensions)-20 °C ... 65 °C
Description of the input (Ambient conditions)Voltage input for redundancy monitoring
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Certificate of classification (Connection data)DNV GL 14085-15HH
Conductor cross section AWG max. (Power supply)12
Conductor cross section AWG min. (Power supply)26
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)< 0.01 %/K
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Fire protection for rail vehicles (DIN EN 45545-2) R22 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2

Product Description

The fault monitoring module is used to evaluate and report collective faults in the fault monitoring system and to monitor the supply voltage. Error signaling is done by means of a NO contact. Screw c
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top