Key Specifications
:0.14 mm² ... 2.5 mm² (without lug)
Link:Screw connection
Depth:119.2 mm
Input:< 1.4 W
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
0.14 mm² ... 2.5 mm² (without lug)
LinkScrew connection
Depth119.2 mm
Input< 1.4 W
width6.2 mm
ThreadM3
height109.81 mm
Marking II (1) G [Ex ia Ga] IIC
isolationDual/reinforced insulation
CertificateCE Compliance
Height range> 2000 m ... 3000 m
Product TypeValve control module
Test voltage2.5 kV AC (50 Hz, 60 s)
Response time< 50 ms
Noise emissionIEC/EN 61000-6-4
Output voltage≥ 10.7 V DC (50 mA)
Product FamilyMINI Analog Pro
No-load voltage> 16 V DC
Output Resistor≥ 103 Ω (internal resistance Rthe)
Current limiting> 50 mA
Number of inputs1
Stripping length10 mm
Number of outputs1
Tightening torque0.5 Nm ... 0.6 Nm
Degree of pollution2 (≤ 5000 m)
Ex i Circuits (EPL)Ga
Degree of protectionIp20
Overvoltage CategoryII (≤ 5000 m)
Standards/ProvisionsIEC/EN 61010-1
Supply voltage rangeSelf-powered in a loop, no external power supply required
Ex Installation (EPL)Gc
Input signal, voltage19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. output power Por888 mW
Max. output current Ior185 mA
Max. output voltage Uor19.2 V
Immunity to disturbancesIEC/EN 61000-6-2
Max. internal choke Lthenegligible
Rated insulation voltage300 VEff
Maximum safety voltage Um253 V AC
Conductor cross-section AWG(converted according to IEC)
Max. C internal capacitythe11 nF
Resistant to short circuitsYes
Electromagnetic CompatibilityTested according to the following standards and requirements: EN 61326-1 Use in an industrial environment, NAMUR NE 21
Rigid conductor cross-section0.2 mm² ... 1.5 mm² (with lug)
Ambient temperature (operating)-40 °C ... 70 °C
Flexible conductor cross-section0.14 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Ambient temperature (storage/transport)-40 °C ... 85 °C
I (simple current circuit): Max. external inductivity Lor/ Max. external capacity Cor10 mH / 8.7 μF
IIA (Simple Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor7 mH / 6.1 μF
IIC (Simple Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor0.8 mH / 240 nF
IIB/IIIC (simple current circuit): Max. external inductivity Lor/ Max. external capacity Cor4 mH / 1.53 μF

Product Description

Ex i, Valve control block for operating intrinsically safe solenoid valves in the Ex. zone No-load voltage: 16 V, current limiting: 50 mA, Loop-powered, Safety Integrity Level (SIL, IEC61508): 3, Scre