Service time: Monday to Friday 9:00-18:00
MINI MCR-EX-SD-16-50-LP-PT - MINI MCR-EX-SD-16-50-LP-PT 1157870 PHOENIX CONTACT Ex i, Valve control block for operating intrinsically saf..
In Stock Hot Product

MINI MCR-EX-SD-16-50-LP-PT

MINI MCR-EX-SD-16-50-LP-PT 1157870 PHOENIX CONTACT Ex i, Valve control block for operating intrinsically saf..

$327.22USD
65 in stock
Key Specifications
:0.14 mm² ... 2.5 mm² (without toe)
Depth:119.2 mm
Width:6.2 mm
Height:109.81 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
0.14 mm² ... 2.5 mm² (without toe)
Depth119.2 mm
Width6.2 mm
Height109.81 mm
Marked II (1) G [Ex ia Ga] IIC
IsolationDouble/reinforced insulation
CertificateCE Compliance
Height Range> 2000 m ... 3000 m
Product TypeValve Control Block
Test voltage2.5 kV AC (50 Hz, 60 sec)
Reaction Time< 50 ms
Output voltage≥ 10.7 V DC (50 mA)
Product FamilyMINI Analog Pro
Supply voltageLoop-powered, no external power required
Surge CategoryII (≤ 5000 m)
Connection typePush-in connection
Protection IndexIP20
Number of Entries1
Number of outputs1
Output Resistance≥ 103 Ω (Inner Resistance Ri)
Power Consumption< 1.4 W
Current Limitation> 50 mA
Degree of pollution2 (≤ 5000 m)
Input Signal Voltage19.2 V DC ... 30 V DC (24 V DC, -20% ... +25%)
Open-circuit voltage> 16 V DC
AWG Conductor Section(Converted according to IEC)
Ex Installation (EPL)Gc
Interference emissionIEC/EN 61000-6-4
Max. output power Por888 mW
Interference resistanceIEC/EN 61000-6-2
Max. Output Current Ior185 mA
Max. output voltage Uor19.2 V
Rigid conductor section0.2 mm² ... 2.5 mm² (with toe cap)
Short circuit resistantYes
Standards/SpecificationsIEC/EN 61010-1
Length to be de-insulated10 mm
Max. Internal Capacity Ci11 nF
Maximum safety voltage Um253 V AC
Sizing Insulation Voltage300 VEff
Flexible conductor section0.14 mm² ... 2.5 mm²
Internal inductance max. Lidespicable
Ambient Temperature (Service)-40 °C ... 70 °C
Electromagnetic compatibilityTesting according to the following standards and requirements: EN 61326-1 for use in the industrial field, NAMUR NE 21
Intrinsically safe circuits (EPL)Ga
Permissible air humidity (service)5 % ... 95% (non-condensing)
Ambient Temperature (Storage/Transport)-40 °C ... 85 °C
I (single electrical circuit): External inductance max. Lor/ Max. external capacity Cor10 mH / 8.7 μF
IIA (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor7 mH / 6.1 μF
IIC (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor0.8 mH / 240 nF
IIB/IIIC (Single Electrical Circuit): External Inductance Max. Lor/ Max. external capacity Cor4 mH / 1.53 μF

Product Description

Ex i-Valve control block for intrinsically safe solenoid valves in the Ex. zone No-load voltage: 16 V DC, current limiting: 50 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IE
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top