| Parameter | Value |
|---|---|
| Potential-free contacts | |
| Link | Push-in connection |
| Depth | 119.2 mm |
| width | 6.2 mm |
| height | 109.81 mm |
| Marking | II (1) G [Ex ia Ga] IIC |
| isolation | Dual/reinforced insulation |
| Certificate | CE Compliance |
| Height range | > 2000 m ... 3000 m |
| Line control | Line fault detection |
| Product Type | Disconnecting amplifier |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Configuration | DIP switch |
| Noise emission | EN 61000-6-4 |
| Product Family | MINI Analog Pro |
| Nominal voltage | 24 V DC |
| Housing Material | PBT |
| Number of inputs | 1 |
| Status Reporting | Green LED (supply voltage) |
| Stripping length | 10 mm |
| Output Description | passive |
| Degree of pollution | 2 (≤ 5000 m) |
| Ex i Circuits (EPL) | Ga |
| Max. inrush current | 50 mA |
| Switching frequency | ≤ 10 kHz (IOUT≥ 5 mA) |
| Degree of protection | Ip20 |
| Overvoltage Category | II (≤ 5000 m) |
| Standards/Provisions | IEC/EN 61010-1 |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Usable input sources | NAMUR Proximity Sensors (IEC/EN 60947-5-6) |
| Ex Installation (EPL) | Gc |
| Installation Location | Choice of |
| Max. output power Por | 28 mW |
| Max. output current Ior | 10.9 mA |
| Max. output voltage Uor | 10.1 V |
| Immunity to disturbances | EN 61000-6-2 |
| Max. internal choke Lthe | negligible |
| Rated insulation voltage | 300 VEff |
| Maximum safety voltage Um | 253 V AC |
| Conductor cross-section AWG | (converted according to IEC) |
| Max. C internal capacitythe | negligible |
| Electromagnetic Compatibility | Tested according to the following standards and requirements: EN 61326-1 Use in an industrial environment, NAMUR NE 21 |
| Rigid conductor cross-section | 0.2 mm² ... 2.5 mm² (with lug) |
| Ambient temperature (operating) | -40 °C ... 70 °C |
| Flexible conductor cross-section | 0.14 mm² ... 2.5 mm² |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| I (mixed current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 100 mH / 1 μF |
| I (simple current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 300 mH / 160 μF |
| IIC (mixed current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 100 mH / 500 nF, 50 mH / 570 nF, 5 mH / 590 nF, 1 mH / 590 nF, 10 μH / 590 nF |
| IIA (Simple Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor | 300 mH / 93 μF |
| IIC (Simple Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor | 300 mH / 2.87 μF |
| IIIC (mixed current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 100 mH / 1 μF |
| IIB/IIA (mixed current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 100 mH / 1 μF |
| IIB/IIIC (simple current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 100 mH / 19.4 μF |
| I/IIB/IIA/IIIC (Mixed Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor | 100 mH / 1 μF, 5 mH / 1 μF, 1 mH / 1 μF, 10 μH / 1 μF |
Technical specifications and performance data
Installation and operation guide