| Parameter | Value |
|---|---|
| 1 V ... 5 V (via DIP switch) | |
| ATEX | Ex II 3 G Ex nA IIC T4 Gc X |
| Color | gray |
| Depth | 120.5 mm |
| Width | 6.2 mm |
| Height | 110.5 mm |
| Conformance | CE-compliant |
| Designation | Electromagnetic RF field |
| Screw thread | M3 |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| No. of channels | 1 |
| Housing material | PBT |
| Number of inputs | 1 |
| Pollution degree | 2 |
| Stripping length | 10 mm |
| UL, USA / Canada | UL 508 Listed |
| Connection method | Screw connection |
| Mounting position | any |
| Number of outputs | 1 |
| Power consumption | ≤ 800 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load) |
| Max. input current | 24 mA |
| Max. input voltage | 33 V |
| Protective circuit | Transient protection |
| Max. output current | 22 mA |
| Current input signal | 0 mA ... 20 mA (via DIP switch) |
| Degree of protection | IP20 |
| Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
| Overvoltage category | II |
| Supply voltage range | 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
| Voltage input signal | 0 V ... 5 V (via DIP switch) |
| Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
| Current output signal | 0 mA ... 20 mA (via DIP switch) |
| Short-circuit current | < 32 mA |
| Standards/regulations | EN 61000-4-3 |
| Voltage output signal | 0 V ... 5 V (via DIP switch) |
| Limit frequency (3 dB) | 30 Hz (via DIP switch) |
| Nominal supply voltage | 24 V DC |
| Step response (10-90%) | < 8.5 ms (with 30 Hz filter) |
| Rated insulation voltage | 300 V (effective) |
| Configurable/programmable | Yes |
| Maximum transmission error | ≤ 0.1 % (of final value) |
| Typical current consumption | 25 mA (Current output, at 24 V DC incl. load) |
| Certificate of classification | DNV GL 14445-15HH |
| Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
| Input resistance current input | approx. 63 Ω |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Load/output load current output | ≤ 600 Ω (at 20 mA) |
| Load/output load voltage output | ≥ 10 kΩ |
| Maximum temperature coefficient | 0.01 %/K |
| Input resistance of voltage input | > 1000 kΩ |
| Test voltage, input/output/supply | 3 kV (50 Hz, 1 min.) |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. AWG conductor cross section, flexible | 12 |
| Min. AWG conductor cross section, flexible | 24 |
| Single conductor/terminal point, solid, with ferrule, max. | 1.5 mm² |
| Single conductor/terminal point, solid, with ferrule, min. | 0.2 mm² |
| Single conductor/terminal point, solid, without ferrule, max. | 2.5 mm² |
| Single conductor/terminal point, solid, without ferrule, min. | 0.2 mm² |
Technical specifications and performance data