Service time: Monday to Friday 9:00-18:00
MINI MCR-2-UI-FRO - MINI MCR-2-UI-FRO 2902031 PHOENIX CONTACT Frequency transducer
In Stock Hot Product

MINI MCR-2-UI-FRO

MINI MCR-2-UI-FRO 2902031 PHOENIX CONTACT Frequency transducer

$0.00USD
3421 in stock
Key Specifications
GTIN:4046356652032
Orderkey:2902031
(General):Class I, Zone 2, Group IIC T6
Catalog page:Page 86 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356652032
Orderkey2902031
(General)Class I, Zone 2, Group IIC T6
Catalog pagePage 86 (C-5-2017)
Depth (Note)120.5 mm
Packing unit1 pc
Width (Note)6.2 mm
Height (Note)110.5 mm
ATEX (General) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T6
(Switching output)13.5 mA (24 V DC)
Custom tariff number85437090
DNV GL-EMC (General)A
(Ambient conditions)0 mA ... 24 mA (can be set via software)
Conformance (General)CE-compliant
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Color (Connection data)gray
Noise emission (General)EN 61000-6-4
UL, USA/Canada (General)UL 508 Listed
DNV GL-Humidity (General)B
Output name (Output data)Switching output
Contact type (Output data)1 N/O contact
DNV GL-Enclosure (General)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (General)A
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
DNV GL-Temperature (General)B
Conformance (Connection data)CE-compliant
Electrical isolation (General)Reinforced insulation in accordance with IEC 61010-1
Number of outputs (Input data)1
Number of outputs (Output data)1
Stripping length (Power supply)10 mm
Connection method (Power supply)Screw connection
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)1
Housing material (Connection data)PBT
Mounting position (Connection data)any
Max. switching current (Output data)100 mA (at 30 V)
Min. switching current (Output data)100 µA
Power consumption (Switching output)≤ 350 mW (9.6 V DC)
Weight per Piece (excluding packing)126.500 g
Degree of pollution (Connection data)2
Number of inputs (Ambient conditions)1
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Connection data)II
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Assembly instructions (Connection data)The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
Electromagnetic compatibility (General)Conformance with EMC directive
Max. input current (Ambient conditions)24 mA
Maximum switching voltage (Output data)30 V DC
Minimum switching voltage (Output data)1 V
Supply voltage range (Switching output)9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
max. input voltage (Ambient conditions)12 V
Current input signal (Ambient conditions)0 mA ... 20 mA (via DIP switch)
Nominal supply voltage (Switching output)24 V DC
Voltage input signal (Ambient conditions)0 V ... 10 V (via DIP switch)
Rated insulation voltage (Connection data)300 V (effective)
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Configurable/programmable (Ambient conditions)Yes
Typical current consumption (Switching output)27 mA (12 V DC)
Certificate of classification (Connection data)DNV GL TAA000021E
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Maximum temperature coefficient (Connection data)< 0.01 %/K
Temperature coefficient, typical (Connection data)0.01 %/K
Input resistance current input (Ambient conditions)approx. 50 Ω (+ 0.7 V for test diode)
Test voltage, input/output/supply (Connection data)3 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Input resistance of voltage input (Ambient conditions)> 120 kΩ
Max. AWG conductor cross section, flexible (Power supply)12
Min. AWG conductor cross section, flexible (Power supply)24
Fire protection for rail vehicles (DIN EN 45545-2) R22 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2
Single conductor/terminal point, solid, with ferrule, max. (Power supply)1.5 mm²
Single conductor/terminal point, solid, with ferrule, min. (Power supply)0.2 mm²
Single conductor/terminal point, solid, without ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. (Power supply)0.2 mm²

Product Description

Analog frequency converter with limit value functionality and plug-in connection technology to convert normalized signals into frequency signals or pulse-modulated signals (PWM). Configurable via DIP
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top