Service time: Monday to Friday 9:00-18:00
MINI MCR-2-TC-UI - MINI MCR-2-TC-UI 2902055 PHOENIX CONTACT Thermocouple measuring transducer
In Stock Hot Product

MINI MCR-2-TC-UI

MINI MCR-2-TC-UI 2902055 PHOENIX CONTACT Thermocouple measuring transducer

$0.00USD
4590 in stock
Key Specifications
GTIN:4046356649766
Orderkey:2902055
(EMC data):Class I, Zone 2, Group IIC T6
Catalog page:Page 82 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356649766
Orderkey2902055
(EMC data)Class I, Zone 2, Group IIC T6
Catalog pagePage 82 (C-5-2017)
Depth (Note)120.5 mm
Packing unit1 pc
Width (Note)6.2 mm
(Input data)< 10 mVrms(at 600 Ω)
Height (Note)110.5 mm
(Output data)66.8 mA (12 V DC)
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T6
Ripple (Input data)< 10 mVrms
Custom tariff number85437090
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant
Designation (EMC data)Conducted interferences
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 508 Listed
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Number of outputs (Input data)1
Electrical isolation (EMC data)Reinforced insulation in accordance with IEC 61010-1
Power consumption (Output data)≤ 850 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)10 mm
Connection method (Power supply)Screw connection
Max. output current (Input data)24.6 mA
Max. output voltage (Input data)approx. 12.3 V
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Standards/regulations (EMC data)EN 61000-4-6
UL, USA/Canada (Connection data)UL 508 Listed
Current output signal (Input data)0 mA ... 20 mA (via DIP switch)
Housing material (Connection data)PBT
Short-circuit current (Input data)< 31.5 mA
Supply voltage range (Output data)9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Voltage output signal (Input data)0 V ... 5 V (via DIP switch)
Mounting position (Connection data)any
Protective circuit (Connection data)Transient protection
Weight per Piece (excluding packing)126.800 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Connection data)II
Assembly instructions (Connection data)The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Typical current consumption (Output data)32.7 mA (24 V DC)
Rated insulation voltage (Connection data)300 V (effective)
Typical cold point errors (Connection data)2 K (2 K + (0,2 K * ΔT))
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Load/output load current output (Input data)≤ 600 Ω (at 20 mA)
Load/output load voltage output (Input data)≥ 10 kΩ
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Configurable/programmable (Ambient conditions)Yes
Certificate of classification (Connection data)DNV GL 14445-15HH
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
Maximum temperature coefficient (Connection data)≤ 0.01 %/K
Transmission error thermocouples (Connection data)0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
Test voltage, input/output/supply (Connection data)3 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types that can be used (TC) (Ambient conditions)B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Max. AWG conductor cross section, flexible (Power supply)12
Min. AWG conductor cross section, flexible (Power supply)24
Typical deviation from the measuring range final value (General)0.05 %
Fire protection for rail vehicles (DIN EN 45545-2) R22 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2
Single conductor/terminal point, solid, with ferrule, max. (Power supply)1.5 mm²
Single conductor/terminal point, solid, with ferrule, min. (Power supply)0.2 mm²
Single conductor/terminal point, solid, without ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. (Power supply)0.2 mm²

Product Description

Configurable temperature converter with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Screw connection technology, standard configuration
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top