| Parameter | Value |
|---|---|
| GTIN | 4055626131566 |
| Orderkey | 2906877 |
| (General) | Class I, Zone 2, Group IIC T6 |
| Catalog page | Page 93 (C-5-2017) |
| Depth (Note) | 120.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 6.2 mm |
| (Input data) | 70 mA (30 V (51 °C ... 70 °C)) |
| Height (Note) | 110.5 mm |
| ATEX (General) | II 3 G Ex nA IIC T4 Gc X |
| Country of origin | DE (Germany) |
| (Connection data) | Class I, Zone 2, Group IIC T6 |
| (Switching output) | 10 mA (24 V DC) |
| Custom tariff number | 85437090 |
| DNV GL-EMC (General) | A |
| (Ambient conditions) | ≤ 50 Ω (Per line, RTD in 2-wire technology) |
| Conformance (General) | CE-compliant |
| ATEX (Connection data) | II 3 G Ex nA IIC T4 Gc X |
| Color (Connection data) | gray |
| Noise emission (General) | EN 61000-6-4 |
| Output name (Input data) | Switching output |
| UL, USA/Canada (General) | UL 508 Listed |
| Contact type (Input data) | 2 N/O contacts |
| DNV GL-Humidity (General) | B |
| DNV GL-Enclosure (General) | Required protection according to the Rules shall be provided upon installation on board |
| DNV GL-Vibration (General) | A |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| DNV GL-Temperature (General) | B |
| Conformance (Connection data) | CE-compliant |
| Electrical isolation (General) | Reinforced insulation in accordance with IEC 61010-1 |
| Number of outputs (Input data) | 2 |
| Stripping length (Power supply) | 10 mm |
| Connection method (Power supply) | Push-in connection |
| Noise emission (Connection data) | EN 61000-6-4 |
| Noise immunity (Connection data) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Status display (Connection data) | Yellow LED (switching output) |
| UL, USA/Canada (Connection data) | UL 508 Listed |
| No. of channels (Connection data) | 1 |
| Housing material (Connection data) | PBT |
| Max. switching current (Input data) | 100 mA (30 V (≤ 50 °C)) |
| Mounting position (Connection data) | any |
| Power consumption (Switching output) | 350 mW |
| Weight per Piece (excluding packing) | 120.500 g |
| Degree of pollution (Connection data) | 2 |
| Number of inputs (Ambient conditions) | 1 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Electrical isolation (Connection data) | Reinforced insulation in accordance with IEC 61010-1 |
| Maximum switching voltage (Input data) | 30 V DC |
| Overvoltage category (Connection data) | II |
| Assembly instructions (Connection data) | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
| Electromagnetic compatibility (General) | Conformance with EMC directive |
| Supply voltage range (Switching output) | 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
| Nominal supply voltage (Switching output) | 24 V DC |
| Sensor input current (Ambient conditions) | approx. 200 µA |
| Connection technology (Ambient conditions) | 2, 3, 4-wire |
| Rated insulation voltage (Connection data) | 300 V |
| Switching point accuracy (Connection data) | < 0.1 % |
| Linear mV signal range (Ambient conditions) | -500 mV ... 500 mV |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 70 °C |
| Available input sources (Ambient conditions) | Thermocouples |
| Utilization restriction (Key Commercial Data) | 1 |
| Typical current consumption (Switching output) | 20 mA (12 V DC) |
| Electromagnetic compatibility (Connection data) | Conformance with EMC directive |
| Maximum temperature coefficient (Connection data) | 0.01 %/K |
| Test voltage, input/output/supply (Connection data) | 3 kV (50 Hz, 1 min.) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section flexible max. (Power supply) | 2.5 mm² |
| Conductor cross section flexible min. (Power supply) | 0.14 mm² |
| Linear resistance measuring range (Ambient conditions) | 0 Ω ... 4000 Ω |
| Sensor types that can be used (TC) (Ambient conditions) | B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L |
| Sensor types (RTD) that can be used (Ambient conditions) | Pt, Ni, Cu sensors |
| Max. AWG conductor cross section, flexible (Power supply) | 12 |
| Min. AWG conductor cross section, flexible (Power supply) | 24 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (General) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (General) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (General) | HL 1 - HL 2 |
| Max. permissible overall conductor resistance (Ambient conditions) | ≤ 25 Ω (Per line, RTD in 3- or 4-wire technology) |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) | HL 1 - HL 2 |
| Single conductor/terminal point, solid, with ferrule, max. (Power supply) | 2.5 mm² |
| Single conductor/terminal point, solid, with ferrule, min. (Power supply) | 0.14 mm² |
| Single conductor/terminal point, solid, without ferrule, max. (Power supply) | 2.5 mm² |
| Single conductor/terminal point, solid, without ferrule, min. (Power supply) | 0.14 mm² |