GTIN:4046356652094
Note:Made to Order (non-returnable)
Orderkey:2902052
(EMC data):Class I, Zone 2, Group IIC T6
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356652094
NoteMade to Order (non-returnable)
Orderkey2902052
(EMC data)Class I, Zone 2, Group IIC T6
Catalog pagePage 80 (C-5-2017)
Depth (Note)120.5 mm
Packing unit1 pc
Width (Note)6.2 mm
(Input data)< 10 mVrms(at 600 Ω)
Height (Note)110.5 mm
(Output data)63 mA (12 V DC)
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T6
Ripple (Input data)< 10 mVrms
Custom tariff number85437090
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant
Designation (EMC data)Conducted interferences
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 508 Listed
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Number of outputs (Input data)1
Electrical isolation (EMC data)Reinforced insulation in accordance with IEC 61010-1
Power consumption (Output data)≤ 850 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)10 mm
Connection method (Power supply)Push-in connection
Max. output current (Input data)24.6 mA
Max. output voltage (Input data)approx. 12.3 V
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Standards/regulations (EMC data)EN 61000-4-6
UL, USA/Canada (Connection data)UL 508 Listed
Current output signal (Input data)0 mA ... 20 mA (via DIP switch)
Housing material (Connection data)PBT
Short-circuit current (Input data)< 31.5 mA
Supply voltage range (Output data)9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Voltage output signal (Input data)0 V ... 5 V (via DIP switch)
Mounting position (Connection data)any
Protective circuit (Connection data)Transient protection
Weight per Piece (excluding packing)110.000 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Connection data)II
Assembly instructions (Connection data)The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Sensor input current (Ambient conditions)approx. 200 µA
Typical current consumption (Output data)32 mA (24 V DC)
Connection technology (Ambient conditions)2, 3, 4-wire
Rated insulation voltage (Connection data)300 V (effective)
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Load/output load current output (Input data)≤ 600 Ω (at 20 mA)
Load/output load voltage output (Input data)≥ 10 kΩ
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Configurable/programmable (Ambient conditions)Yes
Certificate of classification (Connection data)DNV GL 14445-15HH
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
Maximum temperature coefficient (Connection data)0.01 %/K
Test voltage, input/output/supply (Connection data)3 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.14 mm²
Linear resistance measuring range (Ambient conditions)0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
Sensor types (RTD) that can be used (Ambient conditions)Pt, Ni, Cu sensors
Max. AWG conductor cross section, flexible (Power supply)12
Min. AWG conductor cross section, flexible (Power supply)24
Transmission error resistance thermometer (Connection data)0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni)
Transmission error resistance-type sensor (Connection data)2 Ω
Typical deviation from the measuring range final value (General)0.07 %
Fire protection for rail vehicles (DIN EN 45545-2) R22 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2
Single conductor/terminal point, solid, with ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, with ferrule, min. (Power supply)0.14 mm²
Single conductor/terminal point, solid, without ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. (Power supply)0.14 mm²

Product Description

Configurable temperature converter with plug-in connection technology for the connection of 2, 3, 4 conductor resistance heaters and transmitters. Configurable via DIP switch or software. Push-in conn
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top