Service time: Monday to Friday 9:00-18:00
MINI MCR-2-RPSS-I-2I - MINI MCR-2-RPSS-I-2I 2905628 PHOENIX CONTACT Repeater power supply
In Stock Hot Product

MINI MCR-2-RPSS-I-2I

MINI MCR-2-RPSS-I-2I 2905628 PHOENIX CONTACT Repeater power supply

$0.00USD
4174 in stock
Key Specifications
:65 mA (For 24 V DC and in power supply duplicator mode)
EMC:A
Note:When being exposed to interference, there may be minimal deviations.
Type:Signal conditioner
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
65 mA (For 24 V DC and in power supply duplicator mode)
EMCA
NoteWhen being exposed to interference, there may be minimal deviations.
TypeSignal conditioner
Colorgray (RAL 7042)
Depth119.2 mm
Width6.2 mm
Height109.81 mm
Ripple< 20 mVPP(500 Ω)
Altitude≤ 2000 m
CommentsSafety measures must be taken to prevent electrostatic discharge.
EMC noteEMC: class A product, see manufacturer's declaration in the download area
HumidityB
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationA
InsulationReinforced insulation according to IEC/EN 61010-1
CertificateCE-compliant
DesignationElectromagnetic RF field
TemperatureB
Product typeRepeater power supply
Screw threadM3
Test voltage3 kV AC (50 Hz, 60 s)
Assembly noteThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
ConfigurationDIP switches
HART functionYes
Mounting typeDIN rail mounting
Identification II 3 G Ex ec ic IIC T4 Gc
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Product familyMINI Analog Pro
Status displayGreen LED (supply voltage)
No. of channels2
Article revision02
Housing materialPBT
Non-load voltage< 20 V
Number of inputs1
Pollution degree2
Stripping length10 mm
Connection methodScrew connection
Mounting positionany
Number of outputs2
Power consumption1.6 W (at IOUT= 20 mA, 500 Ω load)
Tightening torque0.5 Nm ... 0.6 Nm
Current input signal0 mA ... 20 mA (Signal duplicator mode)
Degree of protectionIP20 (not assessed by UL)
Electrical isolation4-way isolation
Overvoltage categoryII
Supply voltage range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Current output signal0 mA ... 20 mA (Signal duplicator mode)
Ex installation (EPL)Gc
Standards/regulationsEN 61000-4-2
Limit frequency (3 dB)> 1 kHz
Nominal supply voltage24 V DC
Step response (10-90%)< 400 µs
Description of the inputSensor circuit
Rated insulation voltage300 Vrms
Max. current output signal25 mA
Maximum transmission error0.05 % (of final value)
Transmitter supply voltage> 19.5 V
Conductor cross section AWG24 ... 12 (flexible)
Typical current consumption40 mA (For 24 V DC and in signal duplicator mode)
Signal transmission behaviorIn = Out
Conductor cross section rigid0.2 mm² ... 1.5 mm² (with ferrule)
Electromagnetic compatibilityConformance with EMC directive
Input resistance current input90 Ω (+1.6 V)
Ambient temperature (operation)-40 °C ... 70 °C
Load/output load current output≤ 500 Ω (per channel)
Maximum temperature coefficient0.0075 %/K
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Product Description

4-way power duplicator with plug-in connection technology. HART transparency, 0(4) mA input signal ... 20 mA, 0(4) mA output signals ... 20 mA. The device can be used in both signal operating and powe
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top