Key Specifications
GTIN:4055626077949
Note:Made to Order (non-returnable)
Orderkey:2906448
(General):Class I, Zone 2, Group IIC T6
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626077949
NoteMade to Order (non-returnable)
Orderkey2906448
(General)Class I, Zone 2, Group IIC T6
Depth (Note)120.5 mm
GL (General)GL applied for
Packing unit1 pc
Width (Note)6.2 mm
(Input data)4 mA ... 20 mA
Height (Note)110.5 mm
ATEX (General) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T6
Custom tariff number85437090
GL (Connection data)GL applied for
(Ambient conditions)4 mA ... 20 mA
Conformance (General)CE-compliant
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Color (Connection data)gray
Noise emission (General)EN 61000-6-4
Output name (Input data)Current output
UL, USA/Canada (General)UL 508 Listed
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Electrical isolation (General)Reinforced insulation in accordance with IEC 61010-1
Number of outputs (Input data)2
Power consumption (Output data)600 mW (25 mA)
Stripping length (Power supply)10 mm
Connection method (Power supply)Screw connection
Max. output voltage (Input data)30 V
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)2
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PBT
Transmission Behavior (Input data)1:1 to input signal
Voltage output signal (Input data)5 V ... 30 V
Mounting position (Connection data)any
Nominal supply voltage (Output data)no separate supply voltage necessary
Weight per Piece (excluding packing)108.900 g
Degree of pollution (Connection data)2
Number of inputs (Ambient conditions)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)no
Electrical isolation (Connection data)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Connection data)II
Electromagnetic compatibility (General)Conformance with EMC directive
Limit frequency (3 dB) (Connection data)100 Hz
Voltage dissipation (Ambient conditions)5 V
Current input signal (Ambient conditions)0 mA ... 20 mA
Rated insulation voltage (Connection data)300 V (effective)
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Load/output load current output (Input data)600 Ω
Maximum transmission error (Connection data)≤ 0.1 % (At 5 V)
Description of the input (Ambient conditions)Current input
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Configurable/programmable (Ambient conditions)no
Test voltage channel/channel (Connection data)3 kV (50 Hz, 1 min.)
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Transmitter supply voltage (Ambient conditions)UA- 5 V
Maximum temperature coefficient (Connection data)≤ 0.001 %/K
Test voltage, input/output/supply (Connection data)3 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Max. AWG conductor cross section, flexible (Power supply)12
Min. AWG conductor cross section, flexible (Power supply)24
Fire protection for rail vehicles (DIN EN 45545-2) R22 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (General)HL 1 - HL 2
Additional error, depending on the input voltage (Connection data)(UA- 5 V) x 0.06 %
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2
Single conductor/terminal point, solid, with ferrule, max. (Power supply)1.5 mm²
Single conductor/terminal point, solid, with ferrule, min. (Power supply)0.2 mm²
Single conductor/terminal point, solid, without ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. (Power supply)0.2 mm²

Product Description

Two-way splitter powered by output loop with plug-in connection technology for galvanic separation of analogue signals. Input signal = output signal: 0(4)mA ... 20 mA. Screw connection technique.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top