

| Parameter | Value |
|---|---|
| Software | |
| EMC | A |
| Note | When being exposed to interference, there may be minimal deviations. |
| Color | gray (RAL 7042) |
| Depth | 119.2 mm |
| Width | 6.2 mm |
| Height | 109.81 mm |
| Ripple | < 20 mVPP |
| Altitude | ≤ 2000 m |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Humidity | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Vibration | A |
| Insulation | Reinforced insulation according to IEC/EN 61010-1 |
| Certificate | CE-compliant |
| Designation | Electromagnetic RF field |
| Temperature | B |
| Product type | Potiposition transducer |
| Test voltage | 3 kV AC (50 Hz, 60 s) |
| Assembly note | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Configuration | DIP switches |
| Mounting type | DIN rail mounting |
| Identification | II 3 G Ex ec IIC T4 Gc |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Product family | MINI Analog Pro |
| No. of channels | 1 |
| Article revision | 14 |
| Error indication | Red LED |
| Housing material | PBT |
| Non-load voltage | < 17.5 V |
| Number of inputs | 1 |
| Pollution degree | 2 |
| Resistance range | 0 Ω ... 100 Ω |
| Stripping length | 10 mm |
| Connection method | Push-in connection |
| Mounting position | any |
| Number of outputs | 1 |
| Power consumption | ≤ 850 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load) |
| Protective circuit | Transient protection |
| Degree of protection | IP20 (not assessed by UL) |
| Electrical isolation | 3-way isolation |
| Overvoltage category | II |
| Supply voltage range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Current output signal | 0 mA ... 20 mA (via DIP switch) |
| Ex installation (EPL) | Gc |
| Short-circuit current | < 31.5 mA |
| Standards/regulations | EN 61000-4-2 |
| Voltage output signal | 1 V ... 5 V (via DIP switch) |
| Nominal supply voltage | 24 V DC |
| Available input sources | 3-wire potentiometer |
| Step response (0–99%) | < 60 ms |
| Rated insulation voltage | 300 Vrms |
| Operating voltage display | Green LED |
| Max. current output signal | 24.6 mA |
| Max. voltage output signal | 12.3 V |
| Maximum transmission error | < 0.1 % (R < 240 Ω = < 0,2 %) |
| Conductor cross section AWG | 24 ... 12 (flexible) |
| Typical current consumption | 33 mA (24 V DC) |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
| Electromagnetic compatibility | Conformance with EMC directive |
| Resolution, outputs (current) | 2 µA |
| Resolution, outputs (voltage) | 1 mV |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Load/output load current output | ≤ 600 Ω (20 mA) |
| Load/output load voltage output | ≥ 10 kΩ |
| Maximum temperature coefficient | 0.01 %/K |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Temperature coefficient, typical | 0.01 %/K |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Behavior in the event of a sensor error | configurable |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Typical deviation from the measuring range final value | 0.2 % |
Technical specifications and performance data
Installation and operation guide