Service time: Monday to Friday 9:00-18:00
MINI MCR-2-POT-UI-PT - MINI MCR-2-POT-UI-PT 2902017 PHOENIX CONTACT Resistance/potiposition transducer
In Stock Hot Product

MINI MCR-2-POT-UI-PT

MINI MCR-2-POT-UI-PT 2902017 PHOENIX CONTACT Resistance/potiposition transducer

$0.00USD
4638 in stock
Key Specifications
:Software
EMC:A
Note:When being exposed to interference, there may be minimal deviations.
Color:gray (RAL 7042)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Software
EMCA
NoteWhen being exposed to interference, there may be minimal deviations.
Colorgray (RAL 7042)
Depth119.2 mm
Width6.2 mm
Height109.81 mm
Ripple< 20 mVPP
Altitude≤ 2000 m
CommentsSafety measures must be taken to prevent electrostatic discharge.
EMC noteEMC: class A product, see manufacturer's declaration in the download area
HumidityB
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationA
InsulationReinforced insulation according to IEC/EN 61010-1
CertificateCE-compliant
DesignationElectromagnetic RF field
TemperatureB
Product typePotiposition transducer
Test voltage3 kV AC (50 Hz, 60 s)
Assembly noteThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
ConfigurationDIP switches
Mounting typeDIN rail mounting
Identification II 3 G Ex ec IIC T4 Gc
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Product familyMINI Analog Pro
No. of channels1
Article revision14
Error indicationRed LED
Housing materialPBT
Non-load voltage< 17.5 V
Number of inputs1
Pollution degree2
Resistance range0 Ω ... 100 Ω
Stripping length10 mm
Connection methodPush-in connection
Mounting positionany
Number of outputs1
Power consumption≤ 850 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)
Protective circuitTransient protection
Degree of protectionIP20 (not assessed by UL)
Electrical isolation3-way isolation
Overvoltage categoryII
Supply voltage range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Current output signal0 mA ... 20 mA (via DIP switch)
Ex installation (EPL)Gc
Short-circuit current< 31.5 mA
Standards/regulationsEN 61000-4-2
Voltage output signal1 V ... 5 V (via DIP switch)
Nominal supply voltage24 V DC
Available input sources3-wire potentiometer
Step response (0–99%)< 60 ms
Rated insulation voltage300 Vrms
Operating voltage displayGreen LED
Max. current output signal24.6 mA
Max. voltage output signal 12.3 V
Maximum transmission error< 0.1 % (R < 240 Ω = < 0,2 %)
Conductor cross section AWG24 ... 12 (flexible)
Typical current consumption33 mA (24 V DC)
Conductor cross section rigid0.2 mm² ... 2.5 mm² (with ferrule)
Electromagnetic compatibilityConformance with EMC directive
Resolution, outputs (current)2 µA
Resolution, outputs (voltage)1 mV
Ambient temperature (operation)-40 °C ... 70 °C
Load/output load current output≤ 600 Ω (20 mA)
Load/output load voltage output≥ 10 kΩ
Maximum temperature coefficient0.01 %/K
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Temperature coefficient, typical0.01 %/K
Ambient temperature (storage/transport)-40 °C ... 85 °C
Behavior in the event of a sensor errorconfigurable
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2
Typical deviation from the measuring range final value0.2 %

Product Description

Configurable potentiometer position converter with plug-in connection technology for connecting potentiometers from 0 Ω ... 100 Ω at 0 kΩ ... 100 kΩ. Configurable via DIP switch or software. Push-in c
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top