Key Specifications
GTIN:4046356648653
Orderkey:2901994
(General):Class I, Zone 2, Group IIC T6
Catalog page:Page 78 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356648653
Orderkey2901994
(General)Class I, Zone 2, Group IIC T6
Catalog pagePage 78 (C-5-2017)
Depth (Note)120.5 mm
GL (General)GL applied for
Packing unit1 pc
Width (Note)6.2 mm
(Input data)4 mA ... 20 mA
Height (Note)110.5 mm
ATEX (General) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T6
Custom tariff number85437090
GL (Connection data)GL applied for
(Ambient conditions)4 mA ... 20 mA
Conformance (General)CE-compliant
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Color (Connection data)gray
Noise emission (General)EN 61000-6-4
Output name (Input data)Current output
UL, USA/Canada (General)UL 508 Listed
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
Maximum altitude (Dimensions)< 2000 m
Electrical isolation (General)Reinforced insulation in accordance with IEC 61010-1
Number of outputs (Input data)1
Power consumption (Output data)600 mW
Stripping length (Power supply)10 mm
Connection method (Power supply)Screw connection
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PBT
Supply voltage range (Output data)9.6 V DC ... 30 V DC (no separate supply voltage necessary)
Transmission Behavior (Input data)1:1 to input signal
Mounting position (Connection data)any
Weight per Piece (excluding packing)108.000 g
Degree of pollution (Connection data)2
Number of inputs (Ambient conditions)1
Response current (Ambient conditions)approx. 200 µA
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)no
Electrical isolation (Connection data)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Connection data)II
Electromagnetic compatibility (General)Conformance with EMC directive
Limit frequency (3 dB) (Connection data)100 Hz
Voltage dissipation (Ambient conditions)3.1 V (I = 20 mA)
Current input signal (Ambient conditions)0 mA ... 20 mA
Rated insulation voltage (Connection data)300 V (effective)
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Load/output load current output (Input data)< 600 Ω (at I = 20 mA output signal)
Maximum transmission error (Connection data)≤ 0.1 % (of final value)
Description of the input (Ambient conditions)Current input
Input voltage limitation (Ambient conditions)30 V
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Configurable/programmable (Ambient conditions)no
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Maximum temperature coefficient (Connection data)≤ 0.002 %/K (of measured value / 100 Ω load)
Additional error, load-dependent (Connection data)< 0.075 % (of measured value / 100 Ω load)
Test voltage, input/output/supply (Connection data)3 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Max. AWG conductor cross section, flexible (Power supply)12
Min. AWG conductor cross section, flexible (Power supply)24
Fire protection for rail vehicles (DIN EN 45545-2) R22 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (General)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2
Single conductor/terminal point, solid, with ferrule, max. (Power supply)1.5 mm²
Single conductor/terminal point, solid, with ferrule, min. (Power supply)0.2 mm²
Single conductor/terminal point, solid, without ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. (Power supply)0.2 mm²

Product Description

2-way one-channel input loop-fed separator with plug-in connection technology for galvanic separation of analog signals. Input signal = output signal: 0(4)mA ... 20 mA. Screw connection technology.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top