Key Specifications
GTIN:4046356649872
Orderkey:2902056
(EMC data):Class I, Zone 2, Group IIC T5
Catalog page:Page 84 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356649872
Orderkey2902056
(EMC data)Class I, Zone 2, Group IIC T5
Catalog pagePage 84 (C-5-2017)
Depth (Note)120.5 mm
Packing unit1 pc
Width (Note)6.2 mm
(Input data)< 20 mVPP(at 600 Ω)
Height (Note)110.5 mm
(Output data)63 mA (12 V DC)
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T5
Ripple (Input data)< 20 mVPP(at 600 Ω)
Custom tariff number85437090
(Ambient conditions)S0 signal
DNV GL-EMC (EMC data)A
Designation (General)Conducted interferences
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant
Designation (EMC data)Conducted interferences
Color (Connection data)gray
Noise emission (EMC data)EN 61000-6-4
Output name (Output data)Switching output
UL, USA/Canada (EMC data)UL 508 Listed
Contact type (Output data)1 N/O contact
DNV GL-Humidity (EMC data)B
DNV GL-Enclosure (EMC data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (EMC data)A
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant
DNV GL-Temperature (EMC data)B
Number of outputs (Input data)1
Electrical isolation (EMC data)Reinforced insulation in accordance with IEC 61010-1
Number of outputs (Output data)1
Power consumption (Output data)≤ 1 W (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)10 mm
Connection method (Power supply)Screw connection
Max. output current (Input data)24.6 mA
Max. output voltage (Input data)approx. 12.3 V
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Yellow LED (switching output)
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA (via DIP switch)
Housing material (Connection data)PBT
Supply voltage range (Output data)9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Voltage output signal (Input data)0 V ... 10 V (via DIP switch)
Mounting position (Connection data)any
Frequency input (Ambient conditions)Frequency input
Max. switching current (Output data)100 mA (30 V)
Min. switching current (Output data)100 µA
Nominal supply voltage (Output data)24 V DC
Weight per Piece (excluding packing)127.700 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)Reinforced insulation in accordance with IEC 61010-1
Overvoltage category (Connection data)II
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Assembly instructions (Connection data)The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
Maximum switching voltage (Output data)30 V DC
Minimum switching voltage (Output data)1 V
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Typical current consumption (Output data)32 mA (24 V DC)
Rated insulation voltage (Connection data)300 V (effective)
Step response (0–99%) (Switching output)< 35 ms (f > 500 Hz)
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Available input sources (Ambient conditions)NAMUR initiators
Load/output load current output (Input data)≤ 600 Ω (at 20 mA)
Load/output load voltage output (Input data)≥ 10 kΩ
Maximum transmission error (Connection data)0.1 % (Frequency)
Utilization restriction (Key Commercial Data)1
Frequency measuring range (Ambient conditions)0.002 Hz ... 200 kHz
Certificate of classification (Connection data)DNV GL TAA000021E
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Maximum temperature coefficient (Connection data)0.01 %/K
Temperature coefficient, typical (Connection data)0.01 %/K
Test voltage, input/output/supply (Connection data)3 kV (50 Hz, 1 min.)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Max. AWG conductor cross section, flexible (Power supply)12
Min. AWG conductor cross section, flexible (Power supply)24
Typical deviation from the measuring range final value (General)2.8 %
Fire protection for rail vehicles (DIN EN 45545-2) R22 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (EMC data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 2
Single conductor/terminal point, solid, with ferrule, max. (Power supply)1.5 mm²
Single conductor/terminal point, solid, with ferrule, min. (Power supply)0.2 mm²
Single conductor/terminal point, solid, without ferrule, max. (Power supply)2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. (Power supply)0.2 mm²

Product Description

Universally configurable frequency converter for conversion of frequency signals (Hz/rpm) and pulse width modulation into normalized signals. Sensor voltages greater than 8.2 V DC possible in combinat
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data