| Parameter | Value |
|---|---|
| GTIN | 4046356113533 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2866640 |
| Catalog page | Page 301 (C-4-2017) |
| Packing unit | 1 pc |
| (Output data) | 2 kV (routine test) |
| Country of origin | CN (China) |
| Custom tariff number | 85371091 |
| (Ambient conditions) | 1.5 A (120 V AC) |
| Derating (Input data) | 60 °C ... 70 °C (2.5%/K) |
| Screw thread (General) | M3 |
| Efficiency (Input data) | > 83 % |
| Net weight (Output data) | 0.45 kg |
| Stripping length (General) | 8 mm |
| Climatic class (Dimensions) | 3K3 (in acc. with EN 60721) |
| Connection method (General) | Pluggable COMBICON screw connections |
| Depth (Key Commercial Data) | 107 mm |
| IQ technology (Output data) | no |
| Memory medium (Output data) | External, battery 0.8 Ah / 1.3 Ah |
| Width (Key Commercial Data) | 67.5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 99 mm |
| Residual ripple (Input data) | < 50 mVPP |
| Control deviation (Input data) | < 1 % (change in load, static 10 % ... 90 %) |
| Protection class (Output data) | II (in closed control cabinet) |
| Mounting position (Output data) | horizontal DIN rail NS 35, EN 60715 |
| (Connection data for signaling) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
| Buffer time (Ambient conditions) | Can be set to: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; 30 min; permanent |
| Degree of pollution (Dimensions) | 2 |
| Feedback resistance (Input data) | 35 V DC |
| Degree of protection (Dimensions) | IP20 |
| Max. capacitive load (Input data) | unlimited |
| Output current limit (Input data) | max. 3 A |
| Assembly instructions (Output data) | alignable: horizontally 0 mm, vertically 50 mm |
| Connection in parallel (Input data) | No |
| Nominal output voltage (Input data) | 24 V DC |
| Mains buffering (Ambient conditions) | see diagram |
| Weight per Piece (excluding packing) | 495.500 g |
| Screw thread (Connection data, input) | M3 |
| Shock (Connection data for signaling) | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 25; |
| Screw thread (Connection data, output) | M3 |
| Protective circuit (Ambient conditions) | Varistor |
| Voltage (Connection data for signaling) | 10 V |
| Comments (Connection data for signaling) | Criterion B |
| Current consumption (Ambient conditions) | 0.85 A (230 V AC) |
| MTBF (IEC 61709, SN 29500) (Output data) | > 753000 h (40 °C) |
| Nominal output current (IN) (Input data) | 2 A |
| Power loss nominal load max. (Input data) | 15 W |
| Stripping length (Connection data, input) | 8 mm |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 24 |
| Connection method (Connection data, input) | Pluggable COMBICON screw connections |
| Typical response time (Ambient conditions) | 100 ms |
| AC input voltage range (Ambient conditions) | 85 V AC ... 264 V AC |
| Input fuse, integrated (Ambient conditions) | 3.15 A (slow-blow, internal) |
| Input voltage range DC (Ambient conditions) | 100 V DC ... 350 V DC |
| Power factor (cos phi) (Ambient conditions) | approx. 0.5 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| UL approvals (Connection data for signaling) | UL Listed UL 508 |
| Insulation voltage input/output (Output data) | 4 kV (type test) |
| Noise emission (Connection data for signaling) | EN 55011 (EN 55022) |
| Noise immunity (Connection data for signaling) | EN 61000-6-2:2005 |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Frequency range (Connection data for signaling) | 10 kHz ... 80 MHz |
| Nominal input voltage range (Ambient conditions) | 100 V AC ... 240 V AC |
| Contact discharge (Connection data for signaling) | 6 kV |
| Inrush current limiting/I²t (Ambient conditions) | < 1.1 A2s |
| Peak switching voltages nominal load (Input data) | < 100 mVPP |
| Rail applications (Connection data for signaling) | EN 50121-4 |
| Test field strength (Connection data for signaling) | 10 V/m |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Low Voltage Directive (Connection data for signaling) | Conformance with LV directive 2006/95/EC |
| Standards/regulations (Connection data for signaling) | EN 61000-4-11 |
| Vibration (operation) (Connection data for signaling) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| Setting range of the output voltage (USet) (Input data) | 22.5 V DC ... 29.5 V DC (normal mode; in the buffer mode, dependent on a battery voltage of 27.9 V DC ... 19.2 V DC) |
| Conductor cross section AWG max. (Connection data, input) | 12 |
| Conductor cross section AWG min. (Connection data, input) | 24 |
| Standard - Safe isolation (Connection data for signaling) | DIN VDE 0100-410 |
| Conductor cross section AWG max. (Connection data, output) | 12 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Conductor cross section solid max. (Connection data, input) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Max. permissible relative humidity (operation) (Dimensions) | 95 % (at 25 °C, non-condensing) |
| Maximum power dissipation in no-load condition (Input data) | 3.8 W |
| Conductor cross section solid max. (Connection data, output) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| Standard - Electrical safety (Connection data for signaling) | EN 60950-1/VDE 0805 (SELV) |
| Electromagnetic compatibility (Connection data for signaling) | Conformance with EMC Directive 2014/30/EU |
| Surge protection against internal surge voltages (Input data) | < 35 V DC |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Conductor cross section flexible max. (Connection data, output) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Connection in acc. with standard (Connection data for signaling) | CUL |
| Standard – Safety extra-low voltage (Connection data for signaling) | EN 60950-1 (SELV) |
| Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Connection data for signaling) | EN 50178 |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling) | EN 50178/VDE 0160 (PELV) |
Technical specifications and performance data
Installation and operation guide