| Parameter | Value |
|---|---|
| GTIN | 4017918139445 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2814126 |
| Catalog page | Page 136 (C-7-2013) |
| Depth (Note) | 114.5 mm |
| GL (General) | DNV GL |
| Packing unit | 1 pc |
| Width (Note) | 17.5 mm |
| (Input data) | 20 mA ... 4 mA |
| Height (Note) | 99 mm |
| Country of origin | DE (Germany) |
| Ripple (Input data) | < 20 mVPP |
| Custom tariff number | 85437090 |
| GL (Connection data) | DNV GL |
| (Ambient conditions) | Surge protection 30 V DC |
| Conformance (General) | CE-compliant |
| Color (Connection data) | green |
| Output name (Input data) | Voltage output / current output |
| UL, USA/Canada (General) | Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations |
| Output name (Output data) | Transistor output, pnp |
| D/A resolution (Input data) | ± 12 bit |
| Screw thread (Power supply) | M3 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Conformance (Connection data) | CE-compliant |
| Protective circuit (Input data) | Transient protection |
| Stripping length (Power supply) | 8 mm |
| Connection method (Power supply) | Pluggable screw connection |
| Max. output current (Input data) | 24 mA |
| Max. output voltage (Input data) | ± 12 V |
| Output description (Output data) | Can carry a load of 100 mA, switches supply voltage (not protected against short-circuit); locked in case of order-specific configuration, otherwise freely programmable through MCR/PI-CONF-WIN |
| UL, USA/Canada (Connection data) | Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations |
| Current output signal (Input data) | 0 mA ... 20 mA |
| Housing material (Connection data) | Polyamide PA non-reinforced |
| Output voltage range (Output data) | 18 V DC ... 30 V DC (switches supply voltage, not short-circuit resistant) |
| Voltage output signal (Input data) | 0 V ... 5 V |
| Mounting position (Connection data) | any |
| Weight per Piece (excluding packing) | 124.700 g |
| Continuous load current (Output data) | 100 mA |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Configurable/programmable (Input data) | Yes, unconfigured |
| Connection method (Ambient conditions) | Pluggable screw connection |
| Protective circuit (Ambient conditions) | Transient protection |
| Supply voltage range (Switching output) | 18 V DC ... 30 V DC |
| Cold point error, max. (Connection data) | ≤ 3 K |
| Sensor input current (Ambient conditions) | 250 µA (resistance thermometer) |
| Connection in acc. with standard (General) | CUL |
| Connection technology (Ambient conditions) | 2, 3, 4-wire |
| Max. current consumption (Switching output) | ≤ 60 mA |
| Test voltage input/output (Connection data) | 1 kV (50 Hz, 1 min.) |
| Typical cold point errors (Connection data) | 1.5 K |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 65 °C |
| Load/output load current output (Input data) | ≤ 500 Ω |
| Load/output load voltage output (Input data) | ≥ 10 kΩ |
| Maximum transmission error (Connection data) | ≤ 0.1 % (of maximum range, ±6 mV or ±12 µA at output) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Configurable/programmable (Ambient conditions) | Yes, unconfigured |
| Typical current consumption (Switching output) | 40 mA |
| Conductor cross section AWG max. (Power supply) | 14 |
| Conductor cross section AWG min. (Power supply) | 24 |
| Temperature measuring range (Ambient conditions) | Depending on sensor type used |
| Conductor cross section solid max. (Power supply) | 2.5 mm² |
| Conductor cross section solid min. (Power supply) | 0.2 mm² |
| Maximum temperature coefficient (Connection data) | ≤ 0.01 %/K |
| Output current range with wire break (Input data) | 0 A ... 24 mA |
| Output voltage range with wire break (Input data) | -12 V ... 12 V |
| Test voltage input/power supply (Connection data) | 1 kV (50 Hz, 1 min.) |
| Temperature coefficient, typical (Connection data) | 0.005 %/K |
| Conductor cross section flexible max. (Power supply) | 2.5 mm² |
| Conductor cross section flexible min. (Power supply) | 0.2 mm² |
| Linear resistance measuring range (Ambient conditions) | 0 Ω ... 8000 Ω (freely adjustable, min. measuring range 100 Ω) |
| Sensor types that can be used (TC) (Ambient conditions) | U, T, L, J, E, K, N, S, R, B, C, W, HK |
| Sensor types (RTD) that can be used (Ambient conditions) | Pt, Ni, Cu sensors |
| Output current range with overrange/underrange (Input data) | 0 A ... 24 mA |
| Output voltage range with overrange/underrange (Input data) | -12 V ... 12 V |
Technical specifications and performance data