| Parameter | Value |
|---|---|
| GTIN | 4046356566988 |
| Orderkey | 2308098 |
| Catalog page | Page 241 (C-5-2017) |
| Packing unit | 1 pc |
| Country of origin | CN (China) |
| (Connection data) | 0.04 %/K (-40 °C ... 65 °C) |
| Custom tariff number | 90303330 |
| Conformance (General) | CE-compliant |
| Color (Connection data) | green |
| Noise emission (General) | EN 61000-6-4 |
| Noise immunity (General) | EN 61000-6-2 |
| Output name (Input data) | Current output |
| Output name (Output data) | No switching output |
| Depth (Key Commercial Data) | 85 mm |
| Width (Key Commercial Data) | 90 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 33.8 mm |
| Conformance (Connection data) | CE-compliant |
| Connection method (Input data) | Screw connection |
| Stripping length (Power supply) | 10 mm |
| Accuracy class (Connection data) | 1 |
| Max. output current (Input data) | < 25 mA |
| Noise emission (Connection data) | EN 61000-6-4 |
| Noise immunity (Connection data) | EN 61000-6-2 |
| Linearity error (Connection data) | |
| Current output signal (Input data) | 4 mA ... 20 mA |
| Housing material (Connection data) | Frianyl B63 V0 GV30 |
| Weight per Piece (excluding packing) | 293.300 g |
| Degree of pollution (Connection data) | 2 |
| Number of inputs (Ambient conditions) | 1 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 25; |
| Connection method (Ambient conditions) | Cable design: 32 mm diameter |
| Overload capacity (Ambient conditions) | 3 x IIN |
| Overvoltage category (Connection data) | III |
| Supply voltage range (Switching output) | 20 V DC ... 30 V DC |
| Input current range (Ambient conditions) | 0 A ... 600 A |
| Step response (10-90%) (Connection data) | 150 ms |
| Nominal supply voltage (Switching output) | 24 V DC |
| Rated insulation voltage (Connection data) | 300 V AC |
| Max. current consumption (Switching output) | (30 + IOUT) mA |
| Test voltage input/output (Connection data) | 3.5 kV (50 Hz, 1 min.) |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 65 °C |
| Load/output load current output (Input data) | < 300 Ω |
| Maximum transmission error (Connection data) | |
| Frequency measuring range (Ambient conditions) | 20 Hz ... 6000 Hz (0 Hz) |
| Primary rated current Ipn (Ambient conditions) | 600 A |
| Conductor cross section AWG max. (Power supply) | 12 |
| Conductor cross section AWG min. (Power supply) | 24 |
| Conductor cross section solid max. (Power supply) | 2.5 mm² |
| Conductor cross section solid min. (Power supply) | 0.25 mm² |
| Test voltage input/power supply (Connection data) | 3.5 kV (50 Hz, 1 min.) |
| Temperature coefficient, typical (Connection data) | 0.02 %/K (0 ... 60 °C) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section flexible max. (Power supply) | 2.5 mm² |
| Conductor cross section flexible min. (Power supply) | 0.2 mm² |
| Primary round conductor (diameter) (Key Commercial Data) | 32 mm |
| Rated frequency: Standard converter (Ambient conditions) | 20 Hz ... 6000 Hz |
Technical specifications and performance data