| Parameter | Value |
|---|---|
| 40 ms (DC) | |
| Color | green (RAL 6021) |
| Depth | 114.5 mm |
| Width | 22.5 mm |
| Height | 99 mm |
| Altitude | < 2000 m |
| Diameter | 10.5 mm |
| Curve type | AC, DC or distorted currents |
| Certificate | CE-compliant |
| Total error | ≤ 1.5 % (Temperature range) |
| LSB: Current | 1 µA (1 A) |
| Product type | Current transducer |
| Screw thread | M3 |
| Mounting type | DIN rail mounting |
| Identification | Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Status display | LED (green) |
| Surge strength | Depending on through connected conductor |
| Article revision | 02 |
| Housing material | Polyamide PA non-reinforced |
| Pollution degree | 2 |
| Stripping length | 8 mm |
| Connection method | Screw connection |
| Mounting position | any |
| Operate threshold | 1 % (of measuring range nominal value 100 A) |
| Overload capacity | Depending on through connected conductor |
| Measuring category | III |
| Protective circuit | Surge protection; 33 V suppressor diode |
| Input current range | 0 A AC/DC ... 100 A AC/DC (Permitted continuous overload: 120%) |
| Degree of protection | IP20 |
| Overvoltage category | III |
| Supply voltage range | 20 V DC ... 30 V DC |
| Current output signal | 0 mA ... 20 mA |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Standards/regulations | IEC 61010-2-030 |
| Voltage output signal | 0 V ... 10 V |
| Step response (10-90%) | 330 ms (AC) |
| Max. current consumption | < 40 mA (without load) |
| Rated insulation voltage | 300 V AC (to earth) |
| Configurable/programmable | Yes, unconfigured |
| Frequency measuring range | 15 Hz ... 400 Hz |
| Test voltage input/output | 4 kV AC (50 Hz, 60 s) |
| Maximum transmission error | < 0.5 % (of nominal range value under nominal conditions) |
| Conductor cross section AWG | 24 ... 14 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Electromagnetic compatibility | Conformance with EMC directive |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Load/output load current output | < 500 Ω |
| Load/output load voltage output | > 10 kΩ |
| Test voltage input/power supply | 4 kV AC (50 Hz, 60 s) |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Temperature coefficient, typical | < 0.025 %/K |
| Test voltage output/power supply | 500 V AC (50 Hz, 60 s) |
| Setting range for max. input current | 0 A AC/DC ... 100 A AC/DC |
| Setting range for min. input current | 0 A AC/DC ... 19 A AC/DC |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum power dissipation for nominal condition | 2.2 W |
Technical specifications and performance data