| Parameter | Value |
|---|---|
| GTIN | 4017918021054 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1407013 |
| Catalog page | Page 313 (CL-2005) |
| Packing unit | 200 pc |
| Width (General) | 4.5 mm |
| Length (General) | 22 mm |
| Country of origin | DE (Germany) |
| (Connection data) | IEC 60947-7-1 |
| Custom tariff number | 85369010 |
| Height NS 15 (General) | 23 mm |
| Screw thread (Dimensions) | M2,6 |
| Color (Key Commercial Data) | gray |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Stripping length (Dimensions) | 8 mm |
| Connection method (Dimensions) | Screw connection |
| Potentials (Key Commercial Data) | 1 |
| Tightening torque max (Dimensions) | 0.6 Nm |
| Tightening torque, min (Dimensions) | 0.5 Nm |
| Weight per Piece (excluding packing) | 3.200 g |
| Open side panel (Key Commercial Data) | No |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Internal cylindrical gage (Dimensions) | A1 |
| Number of levels (Key Commercial Data) | 1 |
| Nominal current IN (Key Commercial Data) | 16 A (current data for slip-on connections in acc. with DIN 61210 are also dependent on nominal size, material, insulation of the sleeve and conductor cross section.) |
| Nominal voltage UN (Key Commercial Data) | 400 V (voltage data for slip-on connections in acc. with DIN 61210 are also dependent on nominal size, material, insulation of the sleeve and conductor cross section.) |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PA |
| Rated surge voltage (Key Commercial Data) | 6 kV |
| Maximum load current (Key Commercial Data) | 16 A (with a 2.5 mm² conductor cross section) |
| Overvoltage category (Key Commercial Data) | III |
| Number of connections (Key Commercial Data) | 2 |
| Conductor cross section AWG max. (Dimensions) | 14 |
| Conductor cross section AWG min. (Dimensions) | 24 |
| Connection in acc. with standard (Dimensions) | IEC 60947-7-1 |
| Conductor cross section solid max. (Dimensions) | 2.5 mm² |
| Conductor cross section solid min. (Dimensions) | 0.2 mm² |
| Insulating material group (Key Commercial Data) | I |
| Conductor cross section flexible max. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.2 mm² |
| Connection in acc. with standard (Connection data) | CSA |
| Max. AWG conductor cross section, flexible (Dimensions) | 16 |
| Min. AWG conductor cross section, flexible (Dimensions) | 24 |
| Flammability rating according to UL 94 (Connection data) | V2 |
| Cross section with insertion bridge, solid max. (Dimensions) | 1.5 mm² |
| Flammability rating according to UL 94 (Key Commercial Data) | V2 |
| 2 conductors with same cross section, solid max. (Dimensions) | 0.75 mm² |
| 2 conductors with same cross section, solid min. (Dimensions) | 0.2 mm² |
| Cross section with insertion bridge, stranded max. (Dimensions) | 1.5 mm² |
| 2 conductors with same cross section, stranded max. (Dimensions) | 1 mm² |
| 2 conductors with same cross section, stranded min. (Dimensions) | 0.2 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 1 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.25 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions) | 0.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions) | 0.25 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) | 0.75 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) | 0.5 mm² |
Technical specifications and performance data