Key Specifications
GTIN:4046356899277
Note:Made to Order (non-returnable)
Orderkey:2904903
(General):Class I, Zone 2, Group IIC T6
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356899277
NoteMade to Order (non-returnable)
Orderkey2904903
(General)Class I, Zone 2, Group IIC T6
Catalog pagePage 139 (C-5-2017)
Packing unit1 pc
(Input data)0.2 A (120 V DC)
ATEX (General) II 3 G Ex nA nC ic IIC T4 Gc X
IECEx (General)Ex nA nC ic IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T6
Custom tariff number85437090
Conformance (General)CE-compliant
SIL (Connection data)2
ATEX (Connection data) II 3 G Ex nA nC ic IIC T4 Gc X
Color (Connection data)yellow
IECEx (Connection data)Ex nA nC ic IIC T4 Gc X
Output name (Input data)Relay output
UL, USA/Canada (General)UL 508 Listed
Contact type (Input data)2 PDT
Depth (Key Commercial Data)114.5 mm
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Width (Key Commercial Data)35 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)99 mm
Conformance (Connection data)CE-compliant
Contact material (Input data)AgSnO2, hard gold-plated
Designation (Connection data)Input/switching output
Maximum altitude (Dimensions)≤ 2000 m
Electrical isolation (General)4-way, between input/output/power supply/switching output
Output description (Input data)1 SIL/PL
Power consumption (Output data)< 2.4 W
Connection method (Power supply)Push-in connection
UL, USA/Canada (Connection data)UL 508 Listed
Current output signal (Input data)4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Maximum inrush current (Input data)2 A (250 V AC)
Weight per Piece (excluding packing)180.000 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Maximum switching voltage (Input data)250 V AC (250 V DC)
Overvoltage category (Connection data)II
Electromagnetic compatibility (General)Conformance with EMC directive
Input signal range (Ambient conditions)-1000 mV ... 1000 mV
Max. current output signal (Input data)22 mA
Ambient temperature (operation) (Dimensions)-20 °C ... 65 °C
Load/output load current output (Input data)≤ 600 Ω (at 20 mA)
Maximum transmission error (Connection data)0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Permissible humidity (operation) (Dimensions)typ. 5 % ... 95 % (non-condensing)
Conductor cross section AWG max. (Power supply)16
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Flammability rating according to UL 94 (General)V0
Temperature measuring range (Ambient conditions)-200 °C ... 850 °C
Conductor cross section solid max. (Power supply)1.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)0.01 %/K
Potentiometer resistance range (Ambient conditions)0 Ω ... 50 kΩ
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Behavior in the event of a sensor error (Input data)according to NE 43 or freely configurable
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types that can be used (TC) (Ambient conditions)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Flammability rating according to UL 94 (Connection data)V0
Sensor types (RTD) that can be used (Ambient conditions)Pt, Ni, Cu sensors: 2, 3, 4-wire