Service time: Monday to Friday 9:00-18:00
MACX PL-EX-T-UIREL-UP - MACX PL-EX-T-UIREL-UP 2904910 PHOENIX CONTACT Temperature measuring transducer
In Stock Hot Product

MACX PL-EX-T-UIREL-UP

MACX PL-EX-T-UIREL-UP 2904910 PHOENIX CONTACT Temperature measuring transducer

$0.00USD
4948 in stock
Key Specifications
GTIN:4046356899789
Note:Made to Order (non-returnable)
Orderkey:2904910
(EMC data):IIB
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356899789
NoteMade to Order (non-returnable)
Orderkey2904910
(EMC data)IIB
Catalog pagePage 170 (C-5-2017)
Packing unit1 pc
(Input data)0.2 A (120 V DC)
ATEX (EMC data) II (1) G [Ex ia Ga] IIC
Group (General)IIB
Group (EMC data)IIC
IECEx (EMC data)[Ex ia Ga] IIC
Shock (EMC data)15g, according to IEC 60068-2-27
Country of originDE (Germany)
(Connection data)Ex nA nC ic IIC T4 Gc X
Shock (Dimensions)15g, according to IEC 60068-2-27
Custom tariff number85437090
SIL (Connection data)2
ATEX (Connection data) II (1) G [Ex ia Ga] IIC
Conformance (EMC data)CE-compliant
Designation (EMC data)Conducted interferences
Color (Connection data)yellow
IECEx (Connection data)[Ex ia Ga] IIC
Output name (Input data)Relay output
Contact type (Input data)2 PDT
Designation (Safety data)Conducted interferences
UL, USA/Canada (EMC data)UL 508 Listed
Depth (Key Commercial Data)114.5 mm
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
Width (Key Commercial Data)35 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)99 mm
Conformance (Connection data)CE-compliant
Contact material (Input data)AgSnO2, hard gold-plated
Designation (Connection data)Output/supply
Maximum altitude (Dimensions)≤ 2000 m
Max. output power Po (General)11 mW
Electrical isolation (EMC data)4-way, between input/output/power supply/switching output
Output description (Input data)1 SIL/PL
Power consumption (Output data)< 2.4 W
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
Max. output current Io (General)7.4 mA
Max. output voltage Uo (General)6 V
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Green LED (supply voltage, PWR)
UL, USA/Canada (Connection data)UL 508 Listed
Vibration (operation) (EMC data)5g, accordance to IEC 60068-2-6
Current output signal (Input data)4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Vibration (operation) (Dimensions)5g, accordance to IEC 60068-2-6
Max. external capacity Co (General)9.2 µF
Maximum inrush current (Input data)2 A (250 V AC)
Standards/regulations (Safety data)EN 61000-4-6
Mechanical service life (Input data)1x 105cycles
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)180.000 g
Degree of pollution (Connection data)2
Max. internal inductance Li (General)negligible
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
Max. external inductivity Lo (General)10 mH
Max. internal capacitance Ci (General)44 nF
Maximum switching voltage (Input data)250 V AC (250 V DC)
Overvoltage category (Connection data)II
Input signal range (Ambient conditions)-1000 mV ... 1000 mV
Max. current output signal (Input data)22 mA
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Step response (0–99%) (Connection data)typ. 1000 ms (With SIL)
Typical current consumption (Output data)< 100 mA (24 V DC)
Safety-related maximum voltage Um (General)253 V AC/DC
Ambient temperature (operation) (Dimensions)-20 °C ... 65 °C
Load/output load current output (Input data)≤ 600 Ω (20 mA)
Maximum transmission error (Connection data)0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Permissible humidity (operation) (Dimensions)typ. 5 % ... 95 % (non-condensing)
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-200 °C ... 850 °C
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (EMC data)V0
Maximum temperature coefficient (Connection data)0.01 %/K
Potentiometer resistance range (Ambient conditions)0 Ω ... 50 kΩ
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Behavior in the event of a sensor error (Input data)according to NE 43 or freely configurable
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types that can be used (TC) (Ambient conditions)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Flammability rating according to UL 94 (Connection data)V0
Sensor types (RTD) that can be used (Ambient conditions)Pt, Ni, Cu sensors: 2, 3, 4-wire
Typical deviation from the measuring range final value (Safety data)2 %

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top