Service time: Monday to Friday 9:00-18:00
MACX MCR-T-UI-UP - MACX MCR-T-UI-UP 2811394 PHOENIX CONTACT Freely programmable temperature transducer with analog output and 1..
In Stock Hot Product

MACX MCR-T-UI-UP

MACX MCR-T-UI-UP 2811394 PHOENIX CONTACT Freely programmable temperature transducer with analog output and 1..

$0.00USD
3667 in stock
Key Specifications
(General):Class I, Zone 2, Group IIC T6
Depth (Note):114.5 mm
Width (Note):17.5 mm
(Input data):1 A (30 V DC)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
(General)Class I, Zone 2, Group IIC T6
Depth (Note)114.5 mm
Width (Note)17.5 mm
(Input data)1 A (30 V DC)
Height (Note)99 mm
ATEX (General) II 3 G Ex nA nC ic IIC T4 Gc X
IECEx (General)Ex nA nC ic IIC T4 Gc X
UNSPSC 11 (ETIM)39121008
ETIM 4.0 (eCl@ss)EC001596
ETIM 5.0 (eCl@ss)EC002568
(Connection data)Class I, Zone 2, Group IIC T6
UNSPSC 13.2 (ETIM)39121008
UNSPSC 6.01 (ETIM)30211506
UNSPSC 12.01 (ETIM)39121008
UNSPSC 7.0901 (ETIM)39121008
Conformance (General)CE-compliant
ATEX (Connection data) II 3 G Ex nA nC ic IIC T4 Gc X
Color (Connection data)green
IECEx (Connection data)Ex nA nC ic IIC T4 Gc X
Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Output name (Input data)Relay output
Contact type (Input data)1 PDT
UL, USA / Canada (General)UL 508 Listed
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
Conformance (Connection data)CE-compliant
Contact material (Input data)AgSnO2, hard gold-plated
Designation (Connection data)Input/switching output
Maximum altitude (Dimensions)≤ 2000 m
Electrical isolation (General)4-way, between input/output/power supply/switching output
Power consumption (Output data)< 1.5 W
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
Current output signal (Input data)0 mA ... 20 mA ±10 V (in the case of SIL; further free configuration without SIL)
Housing material (Connection data)PA 66-FR
Supply voltage range (Output data)24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
UL, USA / Canada (Connection data)UL 508 Listed
Maximum inrush current (Input data)0.5 A (30 V AC)
Degree of pollution (Connection data)2
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Maximum switching voltage (Input data)30 V AC (30 V DC)
Overvoltage category (Connection data)II
eCl@ss 4.0 (Standards and Regulations)27210107
eCl@ss 4.1 (Standards and Regulations)27210107
eCl@ss 5.0 (Standards and Regulations)27210107
eCl@ss 5.1 (Standards and Regulations)27210107
eCl@ss 6.0 (Standards and Regulations)27210107
eCl@ss 7.0 (Standards and Regulations)27210107
eCl@ss 8.0 (Standards and Regulations)27371503
Electromagnetic compatibility (General)Conformance with EMC directive
Input signal range (Ambient conditions)-1000 mV ... 1000 mV
Max. current output signal (Input data)22 mA
Max. voltage output signal (Input data)± 11 V
Functional Safety (SIL) (Connection data)SIL 2
Ambient temperature (operation) (Dimensions)-20 °C ... 65 °C
Load/output load current output (Input data)≤ 600 Ω (20 mA)
Load/output load voltage output (Input data)≥ 10 kΩ
Permissible humidity (operation) (Dimensions)typ. 5 % ... 95 % (non-condensing)
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Flammability rating according to UL 94 (General)V0
Temperature measuring range (Ambient conditions)-250 °C ... 2500 °C (Range depending on the sensor type)
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)0.01 %/K
Potentiometer resistance range (Ambient conditions)0 Ω ... 50 kΩ
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Behavior in the event of a sensor error (Input data)according to NE 43 or freely configurable
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types that can be used (TC) (Ambient conditions)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Flammability rating according to UL 94 (Connection data)V0
Sensor types (RTD) that can be used (Ambient conditions)Pt, Ni, Cu sensors: 2, 3, 4-wire

Product Description

Freely programmable temperature converter with analog output and 1 limit value relay, standard configuration, heat resistances in 2, 3 or 4 conductor technology, thermocouples, galvanic separation, wi
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top