MACX MCR-SL-TC-I-NC - MACX MCR-SL-TC-I-NC 2924346 PHOENIX CONTACT Temperature measuring transducer
In Stock Hot Product

MACX MCR-SL-TC-I-NC

MACX MCR-SL-TC-I-NC 2924346 PHOENIX CONTACT Temperature measuring transducer

$0.00USD
4934 in stock
Key Specifications
GTIN:4046356515443
Note:Made to Order (non-returnable)
Orderkey:2924346
(EMC data):Class I, Zone 2, Group IIC T4
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356515443
NoteMade to Order (non-returnable)
Orderkey2924346
(EMC data)Class I, Zone 2, Group IIC T4
Catalog pagePage 131 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)4 mA ... 20 mA
GL (EMC data)C, EMC1
Height (Note)99 mm
ATEX (EMC data) II 3G Ex nA ic IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T4
Custom tariff number85437090
GL (Connection data)C, EMC1
Designation (General)Conducted interferences
ATEX (Connection data) II 3G Ex nA ic IIC T4 Gc X
Conformance (EMC data)CE-compliant, additionally EN 61326-1
Designation (EMC data)Conducted interferences
Color (Connection data)gray
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 508 Listed
Signal output (Input data)Current output
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326-1
Designation (Connection data)Input/power supply
Maximum altitude (Dimensions)≤ 2000 m
Power dissipation (Output data)< 1 W
Standards/regulations (General)EN 61000-4-6
Stripping length (Power supply)7 mm
Alignment span (Connection data)± 5 %
Alignment zero (Connection data)± 5 %
Connection method (Power supply)Screw connection
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Green LED (supply voltage, PWR)
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Nominal supply voltage (Output data)24 V DC
Output ripple (current) (Input data)< 50 µAPP
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)122.400 g
Degree of pollution (Connection data)2
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)no
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. current consumption (Output data)< 40 mA (24 V DC)
Overvoltage category (Connection data)II
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Input signal range (Ambient conditions)-20 mV ... 70 mV
Interference emission (Connection data)EN 61000-6-4
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Measuring range span (Ambient conditions)Min. 50 K for thermocouples, 3 mV for mV sources
Step response (0–99%) (Connection data)typ. 700 ms
Typical cold point errors (Connection data)± 1 K
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Load/output load current output (Input data)max. 500 Ω
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-250 °C ... 1372 °C (Range depending on the sensor type)
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (EMC data)V0
Temperature coefficient, typical (Connection data)0.01 %/K
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Behavior in the event of a sensor error (Input data)As per NE 43 or can be freely defined
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Sensor types that can be used (TC) (Ambient conditions)E, J, K, N as per IEC / EN 60584, L as per DIN 43760
Flammability rating according to UL 94 (Connection data)V0

Product Description

Temperature converter, transforms signals from thermocouples and linear mV sources into analog 0/4-20 mA signals. Free programming 3-way galvanic separation, configuration on demand. Replacement item:
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents