| Parameter | Value |
|---|---|
| ≤ 1100 ms | |
| Note | and EN 61326-1 |
| Type | Signal conditioner |
| Color | gray (RAL 7042) |
| Depth | 114.5 mm |
| Width | 12.5 mm |
| Height | 116 mm |
| Altitude | ≤ 2000 m |
| Insulation | Safe isolation in accordance with IEC/EN 61010-1 |
| Application | Temperature |
| Certificate | CE-compliant |
| Designation | Electromagnetic RF field |
| Input signal | Temperature |
| Product type | Temperature transmitter |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Mounting type | DIN rail mounting |
| Alignment span | ± 5 % |
| Alignment zero | ± 5 % |
| Identification | II 3G Ex nA ic IIC T4 Gc X |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Status display | LED supply voltage, PWR (green) |
| Housing material | PA 6.6-FR |
| Number of inputs | 1 |
| Pollution degree | 2 |
| Stripping length | 8 mm |
| Connection method | Push-in connection |
| Number of outputs | 1 |
| Power dissipation | < 1 W |
| Output description | Current output |
| Dimensional drawing | |
| Degree of protection | IP20 (not assessed by UL) |
| Electrical isolation | 3-way isolation |
| Overvoltage category | II |
| Sensor input current | 200 µA ... 1 mA |
| Supply voltage range | 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) |
| Current output signal | 0 mA ... 20 mA |
| Standards/regulations | EN 61000-4-3 |
| Nominal supply voltage | 24 V DC |
| Output ripple (current) | < 50 µAPP |
| Step response (0–99%) | 700 ms |
| Max. current consumption | < 40 mA (24 V DC) |
| Rated insulation voltage | 300 Vrms |
| Configurable/programmable | no |
| Conductor cross section AWG | 24 ... 16 |
| Temperature measuring range | -200 °C ... 850 °C (Range depending on the sensor type) |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Ambient temperature (operation) | -20 °C ... 60 °C (Any mounting position) |
| Load/output load current output | ≤ 500 Ω |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Temperature coefficient, typical | 0.01 %/K |
| Linear resistance measuring range | 0 Ω ... 2000 Ω |
| Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
| Flammability rating according to UL 94 | V0 (Housing) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Behavior in the event of a sensor error | As per NE 43 or can be freely defined |
| Max. permissible overall conductor resistance | 50 Ω (Per cable) |
Technical specifications and performance data