Key Specifications
GTIN:4046356448314
Orderkey:2865955
Catalog page:Page 120 (C-5-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356448314
Orderkey2865955
Catalog pagePage 120 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)0 mA (Cable short-circuit in the input)
Height (Note)112.5 mm
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T4
Custom tariff number85437090
(Ambient conditions)4 mA ... 20 mA
SIL (Connection data)2
ATEX (Connection data) II 3 G Ex nA II T4 Gc X
Color (Connection data)gray
HART function (General)Yes
Designation (Output data)Signal conditioner operation
Output ripple (Input data)< 20 mVrms
Signal output (Input data)Current output (active and passive)
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326
Designation (Connection data)Input/power supply
Maximum altitude (Dimensions)≤ 2000 m
Protocols supported (General)HART
(Data communication (bypass))Class I, Zone 2, Group IIC T4
Power consumption (Output data)< 1.8 W (20 mA / 1000 )
Power dissipation (Output data)< 0.75 W (24 V DC / 20 mA / 1000 )
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
Status display (Connection data)Green LED (supply voltage)
UL, USA/Canada (Connection data)UL 61010 Listed
No. of channels (Connection data)1
Signal input (Ambient conditions)Passive current input
Voltage drop (Ambient conditions)< 3.5 V (in input isolating amplifier operation)
ATEX (Data communication (bypass)) II 3 G Ex nA II T4 Gc X
Current output signal (Input data)0 mA ... 20 mA (active)
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Transmission Behavior (Input data)1:1 to input signal
Nominal supply voltage (Output data)24 V DC
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)126.000 g
Degree of pollution (Connection data)2
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. current consumption (Output data)< 44 mA (24 V DC / 20 mA / 1000 )
Overvoltage category (Connection data)II
DNV GL-EMC (Data communication (bypass))A
Step response (10-90%) (Connection data)< 200 µs (for jump 4 mA ... 20 mA, load 600 Ω)
Conformance (Data communication (bypass))CE-compliant, additionally EN 61326
Current input signal (Ambient conditions)0 mA ... 20 mA
Nominal supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Load/output load current output (Input data)< 1000 Ω (20 mA)
Maximum transmission error (Connection data)< 0.1 % (of final value)
UL, USA/Canada (Data communication (bypass))UL 61010 Listed
DNV GL-Humidity (Data communication (bypass))B
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)< 0.05 % (of final value)
Utilization restriction (Key Commercial Data)1
DNV GL-Enclosure (Data communication (bypass))Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (Data communication (bypass))A
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Transmitter supply voltage (Ambient conditions)> 21.5 V (20 mA)
DNV GL-Temperature (Data communication (bypass))B
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)< 0.01 %/K
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Underload/overload signal range (Ambient conditions)0 mA ... 24 mA (Extended transmission range for diagnostics)
Output behavior in the event of an error (Input data)0 mA (Cable break in the input)
Flammability rating according to UL 94 (Connection data)V0
Electromagnetic compatibility (Data communication (bypass))Conformance with EMC directive
Flammability rating according to UL 94 (Data communication (bypass))V0

Product Description

Input and power signal conditioner, with HART transparency. It transmits 0/4-20 mA powered or active signals at a load (active or passive). 3-way galvanic separation, SIL 2 according to IEC 61508.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide