| Parameter | Value |
|---|---|
| GTIN | 4046356448314 |
| Orderkey | 2865955 |
| Catalog page | Page 120 (C-5-2017) |
| Depth (Note) | 114.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 12.5 mm |
| (Input data) | 0 mA (Cable short-circuit in the input) |
| Height (Note) | 112.5 mm |
| Country of origin | DE (Germany) |
| (Connection data) | Class I, Zone 2, Group IIC T4 |
| Custom tariff number | 85437090 |
| (Ambient conditions) | 4 mA ... 20 mA |
| SIL (Connection data) | 2 |
| ATEX (Connection data) | II 3 G Ex nA II T4 Gc X |
| Color (Connection data) | gray |
| HART function (General) | Yes |
| Designation (Output data) | Signal conditioner operation |
| Output ripple (Input data) | < 20 mVrms |
| Signal output (Input data) | Current output (active and passive) |
| Noise immunity (Dimensions) | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Screw thread (Power supply) | M3 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Conformance (Connection data) | CE-compliant, additionally EN 61326 |
| Designation (Connection data) | Input/power supply |
| Maximum altitude (Dimensions) | ≤ 2000 m |
| Protocols supported (General) | HART |
| (Data communication (bypass)) | Class I, Zone 2, Group IIC T4 |
| Power consumption (Output data) | < 1.8 W (20 mA / 1000 ) |
| Power dissipation (Output data) | < 0.75 W (24 V DC / 20 mA / 1000 ) |
| Stripping length (Power supply) | 7 mm |
| Connection method (Power supply) | Screw connection |
| Status display (Connection data) | Green LED (supply voltage) |
| UL, USA/Canada (Connection data) | UL 61010 Listed |
| No. of channels (Connection data) | 1 |
| Signal input (Ambient conditions) | Passive current input |
| Voltage drop (Ambient conditions) | < 3.5 V (in input isolating amplifier operation) |
| ATEX (Data communication (bypass)) | II 3 G Ex nA II T4 Gc X |
| Current output signal (Input data) | 0 mA ... 20 mA (active) |
| Housing material (Connection data) | PA 6.6-FR |
| Supply voltage range (Output data) | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
| Transmission Behavior (Input data) | 1:1 to input signal |
| Nominal supply voltage (Output data) | 24 V DC |
| Tightening torque max (Power supply) | 0.6 Nm |
| Weight per Piece (excluding packing) | 126.000 g |
| Degree of pollution (Connection data) | 2 |
| Tightening torque, min (Power supply) | 0.5 Nm |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Electrical isolation (Connection data) | 375 V (Peak value in accordance with EN 60079-11) |
| Max. current consumption (Output data) | < 44 mA (24 V DC / 20 mA / 1000 ) |
| Overvoltage category (Connection data) | II |
| DNV GL-EMC (Data communication (bypass)) | A |
| Step response (10-90%) (Connection data) | < 200 µs (for jump 4 mA ... 20 mA, load 600 Ω) |
| Conformance (Data communication (bypass)) | CE-compliant, additionally EN 61326 |
| Current input signal (Ambient conditions) | 0 mA ... 20 mA |
| Nominal supply voltage range (Output data) | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 60 °C (Any mounting position) |
| Load/output load current output (Input data) | < 1000 Ω (20 mA) |
| Maximum transmission error (Connection data) | < 0.1 % (of final value) |
| UL, USA/Canada (Data communication (bypass)) | UL 61010 Listed |
| DNV GL-Humidity (Data communication (bypass)) | B |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (non-condensing) |
| Transmission error, typical (Connection data) | < 0.05 % (of final value) |
| Utilization restriction (Key Commercial Data) | 1 |
| DNV GL-Enclosure (Data communication (bypass)) | Required protection according to the Rules shall be provided upon installation on board |
| DNV GL-Vibration (Data communication (bypass)) | A |
| Conductor cross section AWG max. (Power supply) | 14 |
| Conductor cross section AWG min. (Power supply) | 24 |
| Electromagnetic compatibility (Connection data) | Conformance with EMC directive |
| Transmitter supply voltage (Ambient conditions) | > 21.5 V (20 mA) |
| DNV GL-Temperature (Data communication (bypass)) | B |
| Conductor cross section solid max. (Power supply) | 2.5 mm² |
| Conductor cross section solid min. (Power supply) | 0.2 mm² |
| Maximum temperature coefficient (Connection data) | < 0.01 %/K |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Conductor cross section flexible max. (Power supply) | 2.5 mm² |
| Conductor cross section flexible min. (Power supply) | 0.2 mm² |
| Underload/overload signal range (Ambient conditions) | 0 mA ... 24 mA (Extended transmission range for diagnostics) |
| Output behavior in the event of an error (Input data) | 0 mA (Cable break in the input) |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Electromagnetic compatibility (Data communication (bypass)) | Conformance with EMC directive |
| Flammability rating according to UL 94 (Data communication (bypass)) | V0 |
Technical specifications and performance data
Installation and operation guide