Service time: Monday to Friday 9:00-18:00
MACX MCR-SL-RPSSI-2I - MACX MCR-SL-RPSSI-2I 2924825 PHOENIX CONTACT Repeater power supply
In Stock Hot Product

MACX MCR-SL-RPSSI-2I

MACX MCR-SL-RPSSI-2I 2924825 PHOENIX CONTACT Repeater power supply

$0.00USD
3813 in stock
Key Specifications
GTIN:4046356572040
Orderkey:2924825
(EMC data):Class I, Zone 2, Group IIC T4
Catalog page:Page 121 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356572040
Orderkey2924825
(EMC data)Class I, Zone 2, Group IIC T4
Catalog pagePage 121 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Dimensions)-20 °C ... 70 °C (any mounting position, module distance 5 mm, MTBF reduction factor 2.5, not assessed by UL)
(Input data)0 mA (Cable short-circuit in the input)
Height (Note)112.5 mm
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T4
Custom tariff number85437090
(Ambient conditions)4 mA ... 20 mA
DNV GL-EMC (EMC data)A
SIL (Connection data)2
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant, additionally EN 61326-1
Designation (EMC data)Conducted interferences
Color (Connection data)gray
HART function (General)Yes
Designation (Output data)Signal conditioner operation
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 61010 Listed
DNV GL-Humidity (EMC data)B
Output ripple (Input data)< 20 mVrms
Signal output (Input data)Signal conditioner operation
DNV GL-Enclosure (EMC data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (EMC data)A
Noise immunity (Dimensions)EN 61000-6-2
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326-1
DNV GL-Temperature (EMC data)B
Designation (Connection data)Output 1/output 2
Maximum altitude (Dimensions)≤ 2000 m
Protocols supported (General)HART
Power dissipation (Output data)< 1.2 W (24 V DC / 20 mA)
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Green LED (PWR supply voltage)
UL, USA/Canada (Connection data)UL 61010 Listed
No. of channels (Connection data)1
Signal input (Ambient conditions)Signal conditioner operation
Voltage drop (Ambient conditions)< 3.9 V (in input isolating amplifier operation)
Current output signal (Input data)0 mA ... 20 mA (active)
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Nominal supply voltage (Output data)24 V DC
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)156.000 g
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)1.5 kV AC (50 Hz, 1 min., test voltage)
Max. current consumption (Output data)< 46 mA (24 V DC / 20 mA)
Interference emission (Connection data)EN 61000-6-4
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Step response (10-90%) (Connection data)1.3 ms (for jump 4 mA ... 20 mA, typical)
Current input signal (Ambient conditions)0 mA ... 20 mA
Designation (Data communication (bypass))Conducted interferences
Nominal supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Load/output load current output (Input data)< 450 Ω (20 mA)
Maximum transmission error (Connection data)< 0.1 % (of final value)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)< 0.05 % (of final value)
Utilization restriction (Key Commercial Data)1
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Transmitter supply voltage (Ambient conditions)> 21.5 V (20 mA)
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (EMC data)V0
Maximum temperature coefficient (Connection data)< 0.01 %/K
Standards/regulations (Data communication (bypass))EN 61000-4-6
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Underload/overload signal range (Ambient conditions)0 mA ... 24 mA (Extended transmission range for diagnostics)
Output behavior in the event of an error (Input data)0 mA (Cable break in the input)
Flammability rating according to UL 94 (Connection data)V0
Typical deviation from the measuring range final value (Data communication (bypass))3 %

Product Description

HART Transparent Power Transducer Power Signal Conditioner and Input Signal Conditioner. Transfers 0/4 powered or activated signals... 20 mA galvanically separated from the field in two charges. 4-way
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide