Service time: Monday to Friday 9:00-18:00
MACX MCR-SL-RPSS-2I-2I-SP - MACX MCR-SL-RPSS-2I-2I-SP 2904090 PHOENIX CONTACT Signal isolator
In Stock Hot Product

MACX MCR-SL-RPSS-2I-2I-SP

MACX MCR-SL-RPSS-2I-2I-SP 2904090 PHOENIX CONTACT Signal isolator

$0.00USD
3387 in stock
Key Specifications
GTIN:4046356773362
Note:Made to Order (non-returnable)
Orderkey:2904090
Catalog page:Page 123 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356773362
NoteMade to Order (non-returnable)
Orderkey2904090
Catalog pagePage 123 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)> 22.5 mA (In the event of cable short circuit at the input (as per NE 43))
Height (Note)116 mm
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T4
Custom tariff number85437090
(Ambient conditions)
SIL (Connection data)3
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Color (Connection data)green
HART function (General)Yes
Signal output (Input data)Current output
Noise immunity (Dimensions)EN 61000-6-2
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326
Designation (Connection data)Output 1/output 2/ power supply
Maximum altitude (Dimensions)≤ 2000 m
Protocols supported (General)HART
(Data communication (bypass))Class I, Zone 2, Group IIC T4
Power dissipation (Output data)< 1.4 W (at 24 V DC / 20 mA)
Stripping length (Power supply)8 mm
Connection method (Power supply)Push-in connection
Status display (Connection data)Green LED (supply voltage)
UL, USA/Canada (Connection data)UL 61010 Listed
No. of channels (Connection data)2
ATEX (Data communication (bypass)) II 3 G Ex nA IIC T4 Gc X
Current output signal (Input data)4 mA ... 20 mA (active)
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Transmission Behavior (Input data)1:1 to input signal
Nominal supply voltage (Output data)24 V DC
Weight per Piece (excluding packing)140.000 g
Degree of pollution (Connection data)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)1.5 kV (50 Hz, 1 min., test voltage)
Max. current consumption (Output data)< 100 mA (24 V / 20 mA)
Overvoltage category (Connection data)II
Interference emission (Connection data)EN 61000-6-4
DNV GL-EMC (Data communication (bypass))A
Step response (10-90%) (Connection data)< 1.3 ms (for 4 mA ... 20 mA step)
Conformance (Data communication (bypass))CE-compliant, additionally EN 61326
Current input signal (Ambient conditions)4 mA ... 20 mA
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Load/output load current output (Input data)≤ 450 Ω (20 mA)
Maximum transmission error (Connection data)< 0.1 % (of final value)
Noise emission (Data communication (bypass))EN 61000-6-4
UL, USA/Canada (Data communication (bypass))UL 61010 Listed
DNV GL-Humidity (Data communication (bypass))B
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)< 0.05 % (of final value)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
DNV GL-Enclosure (Data communication (bypass))Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (Data communication (bypass))A
Conductor cross section AWG max. (Power supply)16
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Transmitter supply voltage (Ambient conditions)> 16 V (at 20 mA)
DNV GL-Temperature (Data communication (bypass))B
Conductor cross section solid max. (Power supply)1.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)< 0.01 %/K
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)1.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Underload/overload signal range (Ambient conditions)0 mA ... 24 mA
Output behavior in the event of an error (Input data)< 3.6 mA (In the event of cable break at the input (as per NE 43))
Flammability rating according to UL 94 (Connection data)V0
Electromagnetic compatibility (Data communication (bypass))Conformance with EMC directive
Flammability rating according to UL 94 (Data communication (bypass))V0

Product Description

2-channel power signal conditioner for the operation of 2-conductor measurement transducers, input: 4... 20 mA (power), output: 4 ... 20 mA (active), bidirectional transmission with digital HART trans
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top