Key Specifications
GTIN:4046356449540
Orderkey:2865971
(EMC data):Class I, Zone 2, Group IIC T4
Catalog page:Page 126 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356449540
Orderkey2865971
(EMC data)Class I, Zone 2, Group IIC T4
Catalog pagePage 126 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)< 730 Ω (22.5 mA)
Height (Note)112.5 mm
ATEX (EMC data) II 3 G Ex nA IIC T4 Gc X
Country of originDE (Germany)
(Connection data)Class I, Zone 2, Group IIC T4
Custom tariff number85437090
(Ambient conditions)4 mA ... 20 mA
DNV GL-EMC (EMC data)B
SIL (Connection data)2
ATEX (Connection data) II 3 G Ex nA IIC T4 Gc X
Conformance (EMC data)CE-compliant, additionally EN 61326-1
Designation (EMC data)Electromagnetic RF field
Color (Connection data)gray
HART function (General)Yes
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)UL 508 Listed
DNV GL-Humidity (EMC data)B
Output ripple (Input data)< 20 mVrms
Signal output (Input data)Current output
DNV GL-Enclosure (EMC data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (EMC data)A
Noise immunity (Dimensions)EN 61000-6-2
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326-1
DNV GL-Temperature (EMC data)B
Designation (Connection data)Input/output/power supply
Maximum altitude (Dimensions)≤ 2000 m
Protocols supported (General)HART
(Data communication (bypass))12.2 x 10-4(10 years)
Power dissipation (Output data)< 1.1 W (24 V DC / 20 mA)
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
Standards/regulations (EMC data)EN 61000-4-3
Status display (Connection data)Green LED (supply voltage)
UL, USA/Canada (Connection data)UL 508 Listed
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Transmission Behavior (Input data)1:1 to input signal
λDD (Data communication (bypass))0
λDU (Data communication (bypass))2.79 x 10-8(27.9 FIT)
λSD (Data communication (bypass))0
λSU (Data communication (bypass))4.965 x 10-7(496.5 FIT)
Input impedance (Ambient conditions)> 100 kΩ (If there is a line fault)
Nominal supply voltage (Output data)24 V DC
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)140.900 g
Degree of pollution (Connection data)2
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)1.5 kV (50 Hz, 1 min., test voltage)
Max. current consumption (Output data)< 46 mA (24 V DC / 20 mA)
Overvoltage category (Connection data)II
Interference emission (Connection data)EN 61000-6-4
Designation (Safety characteristic data)Electromagnetic RF field
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Step response (10-90%) (Connection data)< 140 µs (for 4 mA ... 20 mA step)
Current input signal (Ambient conditions)0 mA ... 20 mA
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Equipment type (Data communication (bypass))Type A
Load/output load current output (Input data)< 800 Ω (20 mA)
Maximum transmission error (Connection data)< 0.1 % (of final value)
Input voltage limitation (Ambient conditions)5.4 V (at 20 mA)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)< 0.05 % (of final value)
Utilization restriction (Key Commercial Data)1
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (EMC data)V0
Maximum temperature coefficient (Connection data)< 0.01 %/K
Standards/regulations (Safety characteristic data)EN 61000-4-3
Integrity requirement (Data communication (bypass))IEC 61508 - High demand
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Diagnostic coverage (DC) (Data communication (bypass))DCS=0 %, DCD=0 %
Flammability rating according to UL 94 (Connection data)V0
Safe Failure Fraction (SFF) (Data communication (bypass))94.68 %
Safety Integrity Level (SIL) (Data communication (bypass))2
Probability of a hazardous failure per hour (PFHD) (Data communication (bypass))2,79 x 10-8
Probability of a hazardous failure on demand (PFDAVG) (Data communication (bypass))1.22 x 10-4(1 year)

Product Description

Output signal conditioner, HART. Separates and transmits signals from 0/4-20 mA to a load (I/P converter, control valves, indicators). Cable break detection, SIL 2 according to IEC 61508, screw connec