Service time: Monday to Friday 9:00-18:00
MACX MCR-EX-TC-I - MACX MCR-EX-TC-I 1050233 PHOENIX CONTACT Ex i temperature transducer: converts signals from thermocouples in..
In Stock Hot Product

MACX MCR-EX-TC-I

MACX MCR-EX-TC-I 1050233 PHOENIX CONTACT Ex i temperature transducer: converts signals from thermocouples in..

$0.00USD
4459 in stock
Key Specifications
GTIN:4055626663463
Orderkey:1050233
(Drawings):
(EMC data):IIC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626663463
Orderkey1050233
(Drawings)
(EMC data)IIC
Catalog pagePage 148 (C-5-2019)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)4 mA ... 20 mA (SIL)
Height (Note)112.5 mm
ATEX (EMC data) I (M1) [Ex ia Ma] I
Group (General)IIC
Group (EMC data)IIC/IIB/IIA
IECEx (EMC data)[Ex ia Ma] I
Country of originDE (Germany)
ETIM 5.0 (eCl@ss)EC001446
ETIM 6.0 (eCl@ss)EC002919
ETIM 7.0 (eCl@ss)EC002919
(Connection data)Ex ec ic IIC T4 Gc
Custom tariff number85437090
DNV GL-EMC (EMC data)B
SIL (Connection data)2
Torque (Power supply)0.5 Nm ... 0.6 Nm
ATEX (Connection data) I (M1) [Ex ia Ma] I
Conformance (EMC data)CE-compliant, additionally EN 61326
Designation (EMC data)Conducted interferences
Color (Connection data)gray
IECEx (Connection data)[Ex ia Ma] I
Input power Pi (General)550 mW
Designation (Safety data)Conducted interferences
Noise emission (EMC data)EN 61000-6-4
DNV GL-Humidity (EMC data)B
Input (Ambient conditions)Intrinsically safe
Input current Ii (General)100 mA
Input voltage Ui (General)7 V
Signal output (Input data)Current output
DNV GL-Enclosure (EMC data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (EMC data)A
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
eCl@ss 8.0 (Classifications)27200206
eCl@ss 9.0 (Classifications)27210129
Conformance (Connection data)CE-compliant, additionally EN 61326
DNV GL-Temperature (EMC data)B
Designation (Connection data)Input/power supply
Maximum altitude (Dimensions)≤ 2000 m
Max. output power Po (General)350 mW
Power consumption (Output data)≤ 1 W
Power dissipation (Output data)≤ 0.76 W
Stripping length (Power supply)7 mm
Alignment span (Connection data)± 5 %
Alignment zero (Connection data)± 5 %
Connection method (Power supply)Screw connection
Max. output current Io (General)400 mA
Max. output voltage Uo (General)3.5 V
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Green LED (supply voltage, PWR)
Degree of protection (Dimensions)IP20
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Utilization restriction (Drawings)EMC: class A product, see manufacturer's declaration in the download area
Standards/regulations (Safety data)EN 61000-4-6
Nominal supply voltage (Output data)24 V DC
Output ripple (current) (Input data)< 15 µAPP
Weight per Piece (excluding packing)0.000 g
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. current consumption (Output data)< 40 mA (24 V DC)
Max. external capacitance Co (General)2 µF
Max. external inductivity Lo (General)20 µH
Max. internal capacitance Ci (General)47 µF
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Input signal range (Ambient conditions)-1000 mV ... 1000 mV
Interference emission (Connection data)EN 61000-6-4
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Measuring range span (Ambient conditions)Min. 50 K with thermocouple, 10% of the nominal span of the respective range with mV sources
Step response (0–99%) (Connection data)typ. 700 ms
Conductor cross section AWG (Power supply)24 ... 14
Safety-related maximum voltage Um (General)253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC)
Typical cold point errors (Connection data)± 2 K
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C (Any mounting position)
Conductor cross section solid (Power supply)0.2 mm² ... 2.5 mm²
Load/output load current output (Input data)≤ 600 Ω
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)0.1 % (E.g., for type J, 600 K span, 4 mA ... 20 mA)
Conductor cross section flexible (Power supply)0.2 mm² ... 2.5 mm²
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-250 °C ... 2500 °C (Range depending on the sensor type)
Temperature coefficient, typical (Connection data)0.01 %/K
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Behavior in the event of a sensor error (Input data)As per NE 43 or can be freely defined
Sensor types that can be used (TC) (Ambient conditions)B, E, J, K, N, R, S, T, L, U, C, D, A-1, A-2, A-3, M, Lr
Typical deviation from the measuring range final value (Safety data)1 %

Product Description

Intrinsically Safe Temperature Converter: Transforms signals from thermocouples and mV sources installed in the Ex zone and transmits a 0/4-20 mA signal to a load in the safe zone. Free programming. 3
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide