| Parameter | Value |
|---|---|
| Bürkert Coil AC 10 standard | |
| EMC | A |
| Note | This is an extract of possible combinations of valves and solenoid drivers. |
| Type | Ex i signal conditioners with SIL functional safety |
| Color | gray (RAL 7042) |
| Depth | 113.7 mm |
| Width | 12.5 mm |
| Height | 112.5 mm |
| Altitude | ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
| Humidity | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Vibration | A |
| Insulation | Safe isolation |
| Certificate | CE-compliant |
| Temperature | B |
| Height range | > 2000 m ... 3000 m |
| Product type | Solenoid driver |
| Screw thread | M3 |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Max. diameter | 2 mm |
| Mounting type | DIN rail mounting |
| Response time | < 20 ms |
| Identification | I (M1) [Ex ia Ma] I |
| Input power Pi | negligible |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Output voltage | ≥ 10 V DC (40 mA) |
| Product family | MACX Analog |
| Status display | Yellow LED (switching state / status, lights up when output circuit is active) |
| No. of channels | 1 |
| Article revision | 14 |
| Compatible valve | ASCO Coil 195 |
| Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
| Housing material | PA 6.6-FR |
| Non-load voltage | > 21.9 V DC |
| Number of inputs | 1 |
| Pollution degree | 2 |
| Stripping length | 7 mm |
| Connection method | Screw connection |
| Number of outputs | 1 |
| Power dissipation | < 1.055 W |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Current limitation | > 40 mA |
| Output description | intrinsically safe |
| Dimensional drawing | |
| Ex i circuits (EPL) | Ga |
| Short-circuit-proof | yes |
| Degree of protection | IP20 (not assessed by UL) |
| Electrical isolation | 2-way isolation |
| Max. output power Po | 550 mW |
| Overvoltage category | II |
| Supply voltage range | loop-powered, no external supply necessary |
| Voltage input signal | 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) |
| Ex installation (EPL) | Gc |
| Standards/regulations | IEC/EN 60079-11 |
| Max. output current Io | 87 mA |
| Max. output voltage Uo | 25.1 V |
| Rated insulation voltage | 375 VPP |
| Max. current input signal | 65 mA (Ue= 24 V DC) |
| Conductor cross section AWG | 24 ... 14 |
| Max. internal inductance Li | negligible |
| Max. internal capacitance Ci | negligible |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Electromagnetic compatibility | Conformance with EMC directive |
| Maximum internal resistance Ri | 287 Ω |
| Ambient temperature (operation) | -40 °C ... 60 °C (Any mounting position) |
| Maximum temperature coefficient | 0.01 %/K |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Safety-related maximum voltage Um | 253 V AC |
| Flammability rating according to UL 94 | V0 (Housing) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 2 mH / 50 nF, 0.5 mH / 70 nF, 0.15 mH / 100 nF |
| IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 4.7 mH / 0.108 µF |
| IIA/I (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 20 mH / 600 nF, 5 mH / 610 nF, 1 mH / 640 nF, 0.1 mH / 1000 nF |
| IIA/I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 37.6 mH / 2.93 µF |
| IIB/IIIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 5 mH / 300 nF, 0.5 mH / 500 nF |
| IIB/IIIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 18.8 mH / 0.83 µF |
Technical specifications and performance data
Installation and operation guide