MACX MCR-EX-SL-RTD-I-NC - MACX MCR-EX-SL-RTD-I-NC 2865573 PHOENIX CONTACT Temperature measuring transducer
In Stock Hot Product

MACX MCR-EX-SL-RTD-I-NC

MACX MCR-EX-SL-RTD-I-NC 2865573 PHOENIX CONTACT Temperature measuring transducer

$0.00USD
4944 in stock
Key Specifications
GTIN:4046356160520
Note:Made to Order (non-returnable)
Orderkey:2865573
(EMC data):IIB
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356160520
NoteMade to Order (non-returnable)
Orderkey2865573
(EMC data)IIB
Catalog pagePage 145 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)4 mA ... 20 mA
Height (Note)99 mm
ATEX (EMC data) II (1) G [Ex ia Ga] IIC/IIB
Group (General)IIB
Group (EMC data)IIC
IECEx (EMC data)[Ex ia Ga] IIC
Country of originDE (Germany)
(Connection data)Ex nA ic [ia Ga] IIC T4 Gc
Custom tariff number85437090
ATEX (Connection data) II (1) G [Ex ia Ga] IIC/IIB
Conformance (EMC data)CE-compliant, additionally EN 61326
Designation (EMC data)Conducted interferences
Color (Connection data)gray
IECEx (Connection data)[Ex ia Ga] IIC
Designation (Safety data)Conducted interferences
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)Class I Div 2; IS for Class I, II, III Div 1
Signal output (Input data)Current output
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326
Designation (Connection data)Input/power supply
Maximum altitude (Dimensions)≤ 2000 m
Max. output power Po (General)9.4 mW
Power dissipation (Output data)< 1 W
Stripping length (Power supply)7 mm
Alignment span (Connection data)± 5 %
Alignment zero (Connection data)± 5 %
Connection method (Power supply)Screw connection
Max. output current Io (General)6.3 mA
Max. output voltage Uo (General)6 V
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Green LED (supply voltage, PWR)
UL, USA/Canada (Connection data)Class I Div 2; IS for Class I, II, III Div 1
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC
Max. external capacity Co (General)15 µF
Standards/regulations (Safety data)EN 61000-4-6
Output ripple (current) (Input data)< 50 µAPP
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)170.000 g
Cable resistance (Ambient conditions)≤ 50 Ω per cable
Degree of pollution (Connection data)2
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)no
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. external inductivity Lo (General)1 mH
Overvoltage category (Connection data)II
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Input signal range (Ambient conditions)0 Ω ... 2000 Ω
Interference emission (Connection data)EN 61000-6-4
Measuring range span (Ambient conditions)min. 50 K
Sensor input current (Ambient conditions)200 μA ... 1 mA
Step response (0–99%) (Connection data)typ. 700 ms
Safety-related maximum voltage Um (General)253 V AC (125 V DC)
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Load/output load current output (Input data)≤ 500 Ω
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Temperature measuring range (Ambient conditions)-200 °C ... 850 °C (Range depending on the sensor type)
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (EMC data)V0
Temperature coefficient, typical (Connection data)0.01 %/K
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Behavior in the event of a sensor error (Input data)As per NE 43 or can be freely defined
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (Connection data)V0
Sensor types (RTD) that can be used (Ambient conditions)Sensors (2-, 3-, 4-wire)

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide