Service time: Monday to Friday 9:00-18:00
MACX MCR-EX-SL-RPSSI-2I-1S - MACX MCR-EX-SL-RPSSI-2I-1S 2908855 PHOENIX CONTACT Repeater power supply
In Stock Hot Product

MACX MCR-EX-SL-RPSSI-2I-1S

MACX MCR-EX-SL-RPSSI-2I-1S 2908855 PHOENIX CONTACT Repeater power supply

$0.00USD
3100 in stock
Key Specifications
GTIN:4055626352190
Note:Made to Order (non-returnable)
Orderkey:2908855
Catalog page:Page 141 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626352190
NoteMade to Order (non-returnable)
Orderkey2908855
Catalog pagePage 141 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)0 mA (Cable short-circuit in the input)
Height (Note)99 mm
(Safety data)IIB
Country of originDE (Germany)
(Connection data)Ex nA [ia Ga] IIC T4 Gc
ATEX (Safety data) II (1) G [Ex ia Ga] IIC
Group (Safety data)IIC
IECEx (Safety data)[Ex ia Ga] IIC
Custom tariff number85437090
(Ambient conditions)4 mA ... 20 mA
SIL (Connection data)2
ATEX (Connection data) II (1) G [Ex ia Ga] IIC
Color (Connection data)gray
HART function (General)Yes
IECEx (Connection data)[Ex ia Ga] IIC
DNV GL-EMC (Safety data)A
Conformance (Safety data)CE-compliant, additionally EN 61326
Output ripple (Input data)< 20 mVrms
Signal output (Input data)Signal conditioner operation
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Noise emission (Safety data)EN 61000-6-4
UL, USA/Canada (Safety data)Class I Div 2; IS for Class I, II, III Div 1
Conformance (Connection data)CE-compliant, additionally EN 61326
DNV GL-Humidity (Safety data)B
Designation (Connection data)Output 1/output 2
Maximum altitude (Dimensions)≤ 2000 m
Protocols supported (General)HART
DNV GL-Enclosure (Safety data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (Safety data)A
Power dissipation (Output data)< 1.1 W (24 V DC/ 20 mA)
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
DNV GL-Temperature (Safety data)B
Status display (Connection data)Green LED (PWR supply voltage)
UL, USA/Canada (Connection data)Class I Div 2; IS for Class I, II, III Div 1
No. of channels (Connection data)1
Signal input (Ambient conditions)Signal conditioner operation
Voltage drop (Ambient conditions)approx. 3.9 V (in input isolating amplifier operation)
Current output signal (Input data)0 mA ... 20 mA (active)
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Group (Data communication (bypass))IIB
Nominal supply voltage (Output data)24 V DC
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)175.000 g
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)1.5 kV AC (50 Hz, 1 min., test voltage)
Max. current consumption (Output data)< 46 mA (24 V DC / 20 mA)
Interference emission (Connection data)EN 61000-6-4
Operation (Data communication (bypass))Signal conditioner operation
Step response (10-90%) (Connection data)1.3 ms (Output 1, for jump 4 mA ... 20 mA, typical)
Current input signal (Ambient conditions)0 A ... 20 mA
Electromagnetic compatibility (Safety data)Conformance with EMC directive
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Load/output load current output (Input data)< 450 Ω (20 mA)
Maximum transmission error (Connection data)< 0.1 % (of final value)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)< 0.05 % (of final value)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Input current Ii (Data communication (bypass))≤ 150 mA
Input voltage Ui (Data communication (bypass))≤ 30 V
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Transmitter supply voltage (Ambient conditions)> 16 V (20 mA)
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Maximum temperature coefficient (Connection data)< 0.01 %/K
Max. output power Po (Data communication (bypass))587 mW
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (Safety data)V0
Max. output current Io (Data communication (bypass))93 mA
Max. output voltage Uo (Data communication (bypass))25.2 V
Underload/overload signal range (Ambient conditions)0 mA ... 24 mA (Extended transmission range for diagnostics)
Output behavior in the event of an error (Input data)0 mA (Cable break in the input)
Polarization and surge protection (Ambient conditions)Yes
Max. external capacity Co (Data communication (bypass))820 nF
Flammability rating according to UL 94 (Connection data)V0
Max. internal inductance Li (Data communication (bypass))negligible
Max. external inductivity Lo (Data communication (bypass))4 mH
Max. internal capacitance Ci (Data communication (bypass))negligible
Safety-related maximum voltage Um (Data communication (bypass))253 V AC (125 V DC)

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top