Key Specifications
GTIN:4046356160445
Orderkey:2865434
(General):1.5 x 10-3(5 years)
Catalog page:Page 151 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356160445
Orderkey2865434
(General)1.5 x 10-3(5 years)
Catalog pagePage 151 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)30 V DC (2 A)
Height (Note)99 mm
(Safety data)IIB/IIIC
λDD (General)6 x 10-9(6 FIT)
λDU (General)6.2 x 10-8(62 FIT)
λSD (General)1 x 10-9(1 FIT)
λSU (General)2.48 x 10-7(248 FIT)
Country of originDE (Germany)
(Connection data)UL 61010 Listed
ATEX (Safety data) II (1) G [Ex ia Ga] IIC
Group (Safety data)IIC
IECEx (Safety data)[Ex ia Ga] IIC
Custom tariff number85437090
(Ambient conditions)Short circuit 100 Ω < RSensor < 360 Ω
Designation (General)Inverted operation
SIL (Connection data)2
ATEX (Connection data) II (1) G [Ex ia Ga] IIC
Color (Connection data)gray
IECEx (Connection data)[Ex ia Ga] IIC
DNV GL-EMC (Safety data)B
Equipment type (General)Type A
Conformance (Safety data)CE-compliant, additionally EN 61326
Contact type (Input data)1 PDT
Noise immunity (Dimensions)EN 61000-6-2 EN 61326
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Noise emission (Safety data)EN 61000-6-4
UL, USA/Canada (Safety data)Class I Div 2; IS for Class I, II, III Div 1
Conformance (Connection data)CE-compliant, additionally EN 61326
Contact material (Input data)AgSnO2, hard gold-plated
DNV GL-Humidity (Safety data)B
Designation (Connection data)Input/supply, DIN rail connector
Maximum altitude (Dimensions)≤ 2000 m
Switching output (Input data)Relay output
DNV GL-Enclosure (Safety data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (Safety data)A
Integrity requirement (General)IEC 61508 - Low demand
Power consumption (Output data)< 650 mW
Power dissipation (Output data)< 650 mW
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
DNV GL-Temperature (Safety data)B
Status display (Connection data)Green LED (supply voltage)
Switching frequency (Input data)≤ 20 Hz (without load)
UL, USA/Canada (Connection data)Class I Div 2; IS for Class I, II, III Div 1
No. of channels (Connection data)1
Signal input (Ambient conditions)Intrinsically safe
Diagnostic coverage (DC) (General)DCS= 0.4 %, DCD= 8 %
Group (Safety characteristic data)IIB/IIIC
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Mechanical service life (Input data)107cycles
Nominal supply voltage (Output data)24 V DC -20 % ... +25 %
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)133.000 g
Degree of pollution (Connection data)2
Non-load voltage (Ambient conditions)~ 8 V DC
Safe Failure Fraction (SFF) (General)78 %
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. current consumption (Output data)21 mA (24 V DC)
Maximum switching voltage (Input data)250 V AC (2 A)
Overvoltage category (Connection data)II
Safety Integrity Level (SIL) (General)1
Interference emission (Connection data)EN 61000-6-4
Maximum switching capacity (Input data)500 VA
Line fault detection (Ambient conditions)Break 0.05 mA < IIN < 0.35 mA
Switching hysteresis (Ambient conditions)< 0.2 mA
Short-circuit current (Ambient conditions)~ 8 mA
Electromagnetic compatibility (Safety data)Conformance with EMC directive
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Available input sources (Ambient conditions)NAMUR proximity sensors (IEC/EN 60947-5-6)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)1
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Max. output power Po (Safety characteristic data)25 mW
Switching points (attenuated) (Ambient conditions)< 1.2 mA (blocking)
Max. output current Io (Safety characteristic data)10 mA
Max. output voltage Uo (Safety characteristic data)9.6 V
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (Safety data)V0
Switching points (unattenuated) (Ambient conditions)> 2.1 mA (conductive)
Max. external capacity Co (Safety characteristic data)26 µF
Flammability rating according to UL 94 (Connection data)V0
Max. internal inductance Li (Safety characteristic data)negligible
Max. external inductivity Lo (Safety characteristic data)1000 mH
Max. internal capacitance Ci (Safety characteristic data)11 nF
Safety-related maximum voltage Um (Safety characteristic data)253 V AC (125 V DC)
Probability of a hazardous failure on demand (PFDAVG) (General)3.01 x 10-4(1 year)

Product Description

NAMUR Separation Amplifier, Ex i. For the operation of proximity detectors and switches in the Ex zone. The signals are transmitted via a relay output (switched contact) to the safe zone. Cable Fault
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top