Service time: Monday to Friday 9:00-18:00
MACX MCR-EX-SL-IDSI-I - MACX MCR-EX-SL-IDSI-I 2865405 PHOENIX CONTACT Output signal conditioner
In Stock Hot Product

MACX MCR-EX-SL-IDSI-I

MACX MCR-EX-SL-IDSI-I 2865405 PHOENIX CONTACT Output signal conditioner

$0.00USD
4256 in stock
Key Specifications
GTIN:4046356160421
Orderkey:2865405
(EMC data):IIB
Catalog page:Page 144 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356160421
Orderkey2865405
(EMC data)IIB
Catalog pagePage 144 (C-5-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)< 730 Ω (22.5 mA)
Height (Note)99 mm
ATEX (EMC data) II (1) G [Ex ia Ga] IIC/IIB
Group (EMC data)IIC
IECEx (EMC data)[Ex ia Ga] IIC/IIB
Country of originDE (Germany)
(Connection data)Ex nA [ia Ga] IIC/IIB T4 Gc
Custom tariff number85437090
(Ambient conditions)4 mA ... 20 mA
DNV GL-EMC (EMC data)B
SIL (Connection data)2
ATEX (Connection data) II (1) G [Ex ia Ga] IIC/IIB
Conformance (EMC data)CE-compliant, additionally EN 61326
Designation (EMC data)Electromagnetic RF field
Color (Connection data)gray
HART function (General)Yes
IECEx (Connection data)[Ex ia Ga] IIC/IIB
Designation (Safety data)Electromagnetic RF field
Noise emission (EMC data)EN 61000-6-4
UL, USA/Canada (EMC data)Class I Div 2; IS for Class I, II, III Div 1
DNV GL-Humidity (EMC data)B
Output ripple (Input data)< 20 mVrms
Signal output (Input data)Current output
DNV GL-Enclosure (EMC data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (EMC data)A
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Conformance (Connection data)CE-compliant, additionally EN 61326
DNV GL-Temperature (EMC data)B
Designation (Connection data)Output/supply
Maximum altitude (Dimensions)≤ 2000 m
Protocols supported (General)HART
(Data communication (bypass))12.2 x 10-4(10 years)
Power dissipation (Output data)< 1.1 W (at 24 V DC / 20 mA)
Stripping length (Power supply)7 mm
Connection method (Power supply)Screw connection
Standards/regulations (EMC data)EN 61000-4-3
Status display (Connection data)Green LED (supply voltage)
UL, USA/Canada (Connection data)Class I Div 2; IS for Class I, II, III Div 1
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA (intrinsically safe)
Group (Safety characteristic data)IIB
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Transmission Behavior (Input data)1:1 to input signal
λDD (Data communication (bypass))0
λDU (Data communication (bypass))2.79 x 10-8(27.9 FIT)
λSD (Data communication (bypass))0
λSU (Data communication (bypass))4.965 x 10-7(496.5 FIT)
Standards/regulations (Safety data)EN 61000-4-3
Input impedance (Ambient conditions)> 100 kΩ (If there is a line fault)
Tightening torque max (Power supply)0.6 Nm
Weight per Piece (excluding packing)139.300 g
Degree of pollution (Connection data)2
Tightening torque, min (Power supply)0.5 Nm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. current consumption (Output data)< 46 mA (at 24 V DC / 20 mA)
Overvoltage category (Connection data)II
Interference emission (Connection data)EN 61000-6-4
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Step response (10-90%) (Connection data)< 140 µs (for 4 mA ... 20 mA step)
Current input signal (Ambient conditions)0 mA ... 20 mA
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (Any mounting position)
Equipment type (Data communication (bypass))Type A
Load/output load current output (Input data)< 800 Ω (20 mA)
Maximum transmission error (Connection data)< 0.1 % (of final value)
Input voltage limitation (Ambient conditions)5.4 V (at 20 mA)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)1
Conductor cross section AWG max. (Power supply)14
Conductor cross section AWG min. (Power supply)24
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Conductor cross section solid max. (Power supply)2.5 mm²
Conductor cross section solid min. (Power supply)0.2 mm²
Flammability rating according to UL 94 (EMC data)V0
Max. output power Po (Safety characteristic data)633 mW
Maximum temperature coefficient (Connection data)< 0.01 %/K
Integrity requirement (Data communication (bypass))IEC 61508 - High demand
Max. output current Io (Safety characteristic data)92 mA
Max. output voltage Uo (Safety characteristic data)27.7 V
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible max. (Power supply)2.5 mm²
Conductor cross section flexible min. (Power supply)0.2 mm²
Diagnostic coverage (DC) (Data communication (bypass))DCS=0 %, DCD=0 %
Max. external capacity Co (Safety characteristic data)663 nF
Flammability rating according to UL 94 (Connection data)V0
Max. external inductivity Lo (Safety characteristic data)4 mH
Safe Failure Fraction (SFF) (Data communication (bypass))94.68 %
Safety Integrity Level (SIL) (Data communication (bypass))2
Safety-related maximum voltage Um (Safety characteristic data)253 V AC (125 V DC)
Probability of a hazardous failure per hour (PFHD) (Data communication (bypass))2,79 x 10-8
Probability of a hazardous failure on demand (PFDAVG) (Data communication (bypass))1.22 x 10-4(1 year)

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top