ParameterValue
Floating switch contacts
EMCB
Noteand EN 61326
TypeEx i signal conditioners with SIL functional safety
Colorgray (RAL 7042)
Depth113.7 mm
Width12.5 mm
Height107.9 mm
Altitude≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
HumidityB
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationA
InsulationSafe isolation
ApplicationDigital IN
CertificateCE-compliant
DesignationElectromagnetic RF field
TemperatureB
Height range> 2000 m ... 3000 m
Product typeIsolating switch transf.
Test voltage2.5 kV AC (50 Hz, 60 s)
ConfigurationDIP switches
Mounting typeDIN rail mounting
Identification II (1) G [Ex ia Ga] IIC
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Product familyMACX Analog
Status displayGreen LED (supply voltage)
No. of channels2
Article revision17
Contact materialAgSnO2, hard gold-plated
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)
Housing materialPA 6.6-FR
Non-load voltage8 V DC
Number of inputs2
Pollution degree2
Stripping length10 mm
Connection methodPush-in connection
Number of outputs2
Power consumption< 1 W
Power dissipation< 1 W
Dimensional drawing
Ex i circuits (EPL)Ga
Switching frequency≤ 20 Hz (without load)
Degree of protectionIP20 (not assessed by UL)
Electrical isolation3-way isolation
Evaluation criterionA
Line fault detection< 0.05 mA ... 0.35 mA (Line break)
Max. output power Po25 mW
Overvoltage categoryIII
Supply voltage range19.2 V DC ... 30 V DC
Switching hysteresis< 0.2 mA
Ex installation (EPL)Gc
Short-circuit current8 mA
Standards/regulationsIEC/EN 60079-11
Contact switching type1 N/O contact per channel
Max. output current Io10 mA
Max. output voltage Uo9.6 V
Nominal supply voltage24 V DC -20 % ... +25 %
Available input sourcesNAMUR proximity sensors (IEC/EN 60947-5-6)
Description of the inputIntrinsically safe
Max. current consumption35 mA (24 V DC)
Rated insulation voltage375 VPP
Recommended minimum load5 V / 10 mA
Maximum switching voltage250 V AC (2 A)
Maximum switching capacity500 VA
Conductor cross section AWG24 ... 14
Max. internal inductance Linegligible
Max. internal capacitance Ci11 nF
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Electromagnetic compatibilityConformance with EMC directive
Ambient temperature (operation)-40 °C ... 60 °C (Any mounting position)
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Safety-related maximum voltage Um253 V AC
Flammability rating according to UL 94V0 (Housing)
Switching threshold "0" signal current< 1.2 mA (blocking)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Switching threshold "1" signal, current> 2.1 mA (conductive)
Electrical isolation between input and outputyes
Maximum power dissipation for nominal condition< 1 W
Conductor cross section flexible (2 conductors with same cross section)0.25 mm² ... 0.34 mm² (TWIN ferrule without plastic sleeve)
IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co100 mH / 500 nF, 50 mH / 570 nF, 5 mH / 590 nF, 1 mH / 590 nF, 10 µH / 590 nF
IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co300 mH / 3.6 µF
IIA/I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co1000 mH / 210 µF
IIB/IIIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co1000 mH / 26 µF
I/IIB/IIA/IIIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co100 mH / 1 µF, 5 mH / 1 µF, 1 mH / 1 µF, 10 µH / 1 µF

Product Description

NAMUR Ex i separation amplifier, 2 channels. For the operation of proximity detectors and switches in the Ex zone. The signals are transmitted via relay outputs (open contacts) to the safe area. Fault
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top