Service time: Monday to Friday 9:00-18:00
MACX MCR-EX-RTD-I - MACX MCR-EX-RTD-I 1050222 PHOENIX CONTACT Ex i temperature transducer: converts signals from resistance temp..
In Stock Hot Product

MACX MCR-EX-RTD-I

MACX MCR-EX-RTD-I 1050222 PHOENIX CONTACT Ex i temperature transducer: converts signals from resistance temp..

$0.00USD
4665 in stock
Key Specifications
GTIN:4055626666075
Orderkey:1050222
(Drawings):
(EMC data):IIC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626666075
Orderkey1050222
(Drawings)
(EMC data)IIC
Catalog pagePage 146 (C-5-2019)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
(Input data)4 mA ... 20 mA (SIL)
Height (Note)112.5 mm
ATEX (EMC data) I (M1) [Ex ia Ma] I
Group (General)IIC
Group (EMC data)IIC/IIB/IIA
IECEx (EMC data)[Ex ia Ma] I
UNSPSC 11 (ETIM)39121008
Country of originDE (Germany)
ETIM 2.0 (eCl@ss)EC001446
ETIM 3.0 (eCl@ss)EC001446
ETIM 4.0 (eCl@ss)EC001446
ETIM 5.0 (eCl@ss)EC001446
ETIM 6.0 (eCl@ss)EC002919
ETIM 7.0 (eCl@ss)EC002919
(Connection data)Ex ec ic IIC T4 Gc
UNSPSC 13.2 (ETIM)41112105
UNSPSC 18.0 (ETIM)41112105
UNSPSC 19.0 (ETIM)41112105
UNSPSC 20.0 (ETIM)41112105
UNSPSC 21.0 (ETIM)41112105
UNSPSC 6.01 (ETIM)30211506
UNSPSC 12.01 (ETIM)39121008
Custom tariff number85437090
UNSPSC 7.0901 (ETIM)39121008
DNV GL-EMC (EMC data)B
SIL (Connection data)2
Torque (Power supply)0.5 Nm ... 0.6 Nm
ATEX (Connection data) I (M1) [Ex ia Ma] I
Conformance (EMC data)CE-compliant, additionally EN 61326
Designation (EMC data)Conducted interferences
Color (Connection data)gray
IECEx (Connection data)[Ex ia Ma] I
Input power Pi (General)550 mW
Designation (Safety data)Conducted interferences
Noise emission (EMC data)EN 61000-6-4
DNV GL-Humidity (EMC data)B
Input (Ambient conditions)Intrinsically safe
Input current Ii (General)100 mA
Input voltage Ui (General)7 V
Signal output (Input data)Current output
DNV GL-Enclosure (EMC data)Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (EMC data)A
Noise immunity (Dimensions)EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Screw thread (Power supply)M3
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
eCl@ss 4.0 (Classifications)27210120
eCl@ss 4.1 (Classifications)27210120
eCl@ss 5.0 (Classifications)27210120
eCl@ss 5.1 (Classifications)27210120
eCl@ss 6.0 (Classifications)27210120
eCl@ss 7.0 (Classifications)27210120
eCl@ss 8.0 (Classifications)27200206
eCl@ss 9.0 (Classifications)27210129
Conformance (Connection data)CE-compliant, additionally EN 61326
DNV GL-Temperature (EMC data)B
Designation (Connection data)Input/power supply
Max. output power Po (General)350 mW
Power consumption (Output data)≤ 1 W
Power dissipation (Output data)≤ 0.76 W
Stripping length (Power supply)7 mm
Alignment span (Connection data)± 5 %
Alignment zero (Connection data)± 5 %
Connection method (Power supply)Screw connection
Max. output current Io (General)400 mA
Max. output voltage Uo (General)3.5 V
Standards/regulations (EMC data)EN 61000-4-6
Status display (Connection data)Green LED (supply voltage, PWR)
Degree of protection (Dimensions)IP20
No. of channels (Connection data)1
Current output signal (Input data)0 mA ... 20 mA
Housing material (Connection data)PA 6.6-FR
Supply voltage range (Output data)19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Utilization restriction (Drawings)EMC: class A product, see manufacturer's declaration in the download area
Standards/regulations (Safety data)EN 61000-4-6
Nominal supply voltage (Output data)24 V DC
Output ripple (current) (Input data)< 15 µAPP
Weight per Piece (excluding packing)0.000 g
Cable resistance (Ambient conditions)≤ 50 Ω per cable
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Configurable/programmable (Input data)Yes
Electrical isolation (Connection data)375 V (Peak value in accordance with EN 60079-11)
Max. external capacitance Co (General)2 µF
Max. external inductivity Lo (General)20 µH
Max. internal capacitance Ci (General)47 µF
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Input signal range (Ambient conditions)0 Ω ... 50 kΩ
Interference emission (Connection data)EN 61000-6-4
Electromagnetic compatibility (EMC data)Conformance with EMC directive
Measuring range span (Ambient conditions)≥ 50 K
Sensor input current (Ambient conditions)10 µA ... 210 µA (up to 2 x 210 µA for 3-conductor)
Step response (0–99%) (Connection data)typ. 1 s
Conductor cross section AWG (Power supply)24 ... 14
Safety-related maximum voltage Um (General)253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC)
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C (Any mounting position)
Conductor cross section solid (Power supply)0.2 mm² ... 2.5 mm²
Load/output load current output (Input data)≤ 600 Ω
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Transmission error, typical (Connection data)0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Conductor cross section flexible (Power supply)0.2 mm² ... 2.5 mm²
Electromagnetic compatibility (Connection data)Conformance with EMC directive
Temperature measuring range (Ambient conditions)-200 °C ... 850 °C (Range depending on the sensor type)
Temperature coefficient, typical (Connection data)0.01 %/K
Potentiometer resistance range (Ambient conditions)0 Ω ... 50 kΩ
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Behavior in the event of a sensor error (Input data)As per NE 43 or can be freely defined
Sensor types (RTD) that can be used (Ambient conditions)Sensors (2-, 3-, 4-wire)
Typical deviation from the measuring range final value (Safety data)1 %

Product Description

Intrinsically Safe Temperature Converter: Converts the signals from the thermoresistors installed in the Ex zone and transmits a 0/4-20 mA signal to a load in the safe area. Free programming. 3-way sp
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top