| Parameter | Value |
|---|---|
| ≤ 100 Ω (per wire, 3-, 4-conductor circuit) | |
| Depth | 113.7 mm |
| Width | 17.5 mm |
| Height | 112.5 mm |
| General | Accuracy, typically specified as a percentage of the basic measuring range at UN, 23°C |
| Altitude | ≤ 2000 m |
| Product type | Temperature transmitter |
| Screw thread | M3 |
| Test voltage | 350 V (50 Hz, 60 s) |
| Mounting type | NS 35/15, NS 35/7,5 |
| Setting range | < 1 s (Input/output) |
| Settling time | < 10 ms (10% ... 90%, multiplexer mode) |
| Identification | II (1) G [Ex ia Ga] IIC |
| Product family | MACX Analog |
| Status display | Green LED (supply voltage) |
| No. of channels | 1 |
| Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
| Housing material | Polyamide (PA 6.6) |
| Stripping length | 7 mm |
| Connection method | Screw connection |
| Cross section AWG | (converted acc. to IEC) |
| Mounting position | vertical, horizontal |
| Power consumption | ≤ 650 mW |
| Power dissipation | ≤ 600 mW |
| Dimensional drawing | |
| Ex i circuits (EPL) | Ga |
| Degree of protection | IP20 (Terminal blocks) |
| Electrical isolation | 3-way isolation |
| Max. output power Po | 27 mW |
| Sensor input current | 200 µA ... 5 mA |
| Supply voltage range | 18 V ... 31.2 V |
| Connection technology | 2-, 3-, 4-conductor |
| Ex installation (EPL) | Gc |
| Output signal Current | 5 mA (Nominal current) |
| Output signal Voltage | 2 V DC (Nominal voltage) |
| Standards/regulations | IEC/EN 60079-11 |
| Max. output current Io | 16.5 mA |
| Max. output voltage Uo | 6.5 V |
| Max. switching current | 100 mA |
| Nominal supply voltage | 24 V DC |
| Description of the input | Intrinsically safe |
| Output signal Resistance | 400 Ω |
| Rated insulation voltage | 375 VPP |
| Maximum switching voltage | 30 V |
| Conductor cross section AWG | 24 ... 14 |
| Max. internal inductance Li | negligible |
| Reverse polarity protection | yes |
| Max. internal capacitance Ci | negligible |
| Signal transmission behavior | In = Out |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Electromagnetic compatibility | Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 |
| Output signal Resistance range | 18 Ω ... 391 Ω (Pt 100) |
| Ambient temperature (operation) | -20 °C ... 70 °C (Stand-alone device: any mounting position) |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Permissible humidity (operation) | ≤ 95 % (non-condensing) |
| Temperature coefficient, typical | ≤ 0.1 % (10 K) |
| Linear resistance measuring range | 18 Ω ... 391 Ω (Pt 100) |
| Safety-related maximum voltage Um | 253 V AC |
| Sensor types (RTD) that can be used | Pt 100 |
| Flammability rating according to UL 94 | V0 |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Max. permissible overall conductor resistance | ≤ 50 Ω (per wire, 2-conductor circuit) |
| I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 1000 mH / 1000 µF |
| IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 50 mH / 1.1 µF, 5 mH / 1.7 µF, 1 mH / 2.3 µF, 0.2 mH / 3.4 µF |
| IIA (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 900 mH / 1000 µF |
| IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 120 mH / 25 µF |
| IIB/IIIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 100 mH / 5.3 µF, 20 mH / 6.9 µF, 2 mH / 11 µF, 0.5 mH / 15 µF |
| IIB/IIIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 450 mH / 570 µF |
Technical specifications and performance data
Installation and operation guide