Key Specifications
:100 Ω (per wire, 3-, 4-conductor circuit)
Load:0 Ω ... 600 Ω (per channel)
Depth:113.7 mm
Width:17.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
100 Ω (per wire, 3-, 4-conductor circuit)
Load0 Ω ... 600 Ω (per channel)
Depth113.7 mm
Width17.5 mm
Height112.5 mm
GeneralAccuracy, typically specified as a percentage of the basic measuring range at UN, 23°C
Altitude≤ 2000 m
Product typeTemperature transmitter
Screw threadM3
Test voltage350 V (50 Hz, 60 s)
ConfigurationSoftware
Mounting typeNS 35/15, NS 35/7,5
Identification II (1) G [Ex ia Ga] IIC
Product familyMACX Analog
Status displayGreen LED (supply voltage)
No. of channels2
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)
Housing materialPolyamide (PA 6.6)
Stripping length7 mm
Connection methodScrew connection
Cross section AWG(converted acc. to IEC)
Mounting positionvertical, horizontal
Power consumption≤ 1.9 W
Power dissipation≤ 1.9 W
Dimensional drawing
Ex i circuits (EPL)Ga
Degree of protectionIP20 (Terminal blocks)
Electrical isolation5-way isolation
Max. output power Po32 mW (linear characteristic curve)
Supply voltage range18 V ... 31.2 V
Connection technology2-, 3-, 4-conductor
Current output signal0 mA ... 20 mA (configurable)
Ex installation (EPL)Gc
Standards/regulationsIEC/EN 60079-11
Max. output current Io19.7 mA
Max. output voltage Uo6.5 V
Max. switching current100 mA
Nominal supply voltage24 V DC
Description of the inputResistance temperature detector
Rated insulation voltage375 VPP
Maximum switching voltage30 V
Conductor cross section AWG24 ... 14
Max. internal inductance Linegligible
Reverse polarity protectionyes
Temperature measuring range-200 °C ... 1100 °C (Range depending on the sensor type)
Max. internal capacitance Cinegligible
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Electromagnetic compatibilityTested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21
Ambient temperature (operation)-20 °C ... 70 °C (Stand-alone device: any mounting position)
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)≤ 95 % (non-condensing)
Temperature coefficient, typical≤ 0.1 % (10 K)
Linear resistance measuring range50 Ω ... 500 Ω
Safety-related maximum voltage Um253 V AC
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, XK
Sensor types (RTD) that can be usedPt 100, Pt 250, Pt 500, Pt 1000, Pt 2000, Ni 100, Ni 500, Ni 1000, M50, M53, M100
Flammability rating according to UL 94V0
Ambient temperature (storage/transport)-40 °C ... 80 °C
Max. permissible overall conductor resistance50 Ω (per wire, 2-conductor circuit)
I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co700 mH / 1000 µF
IIA (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co700 mH / 1000 µF
IIB (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co330 mH / 570 µF
IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co90 mH / 25 µF

Product Description

Ex i, Temperature converters, Ex i input signals of resistance thermometers in 2, 3 or 4 conductor technology, thermocouples and mV sources are converted to 0 mA / 4 mA non-Ex i signals... 20 mA activ
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top