Key Specifications
:100 Ω (per wire, 3, 4 conductor circuit)
Load:0 Ω ... 600 Ω (per channel)
Depth:113.7 mm
Width:17.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
100 Ω (per wire, 3, 4 conductor circuit)
Load0 Ω ... 600 Ω (per channel)
Depth113.7 mm
Width17.5 mm
Height107.8 mm
Marked II (1) G [Ex ia Ga] IIC
GeneralAccuracy, typical data in % of the basic measurement interval with UN, 23 °C
Altitude≤ 2000 m
Product TypeTemperature Converter
Test voltage350 V (50 Hz, 60 sec)
ConfigurationSoftware
Product FamilyMACX Analog
Shell materialPolyamide (PA 6.6)
Supply voltage18 V ... 31.2 V
Connection typePush-in connection
Depth NS 35/7.5114.5 mm (fitted on DIN rail NS 35/7.5 according to EN 60715)
Dimension Scheme
Dissipated Power≤ 1.9 W
Protection IndexIP20 (Terminals)
Type of mountingNS 35/15, NS 35/7.5
Power Consumption≤ 1.9 W
Status IndicationGreen LED (supply voltage)
Number of channels2
Ticket DescriptionHeat resistance
Galvanic Separation5-way spacing
AWG Conductor Section(Converted according to IEC)
Connection technology2, 3, 4 conductors
Current Output Signal0 mA ... 20 mA (configurable)
Ex Installation (EPL)Gc
Max. output power Por32 mW (linear characteristic curve)
Position for mountingvertical, horizontal
Nominal Supply Voltage24 V DC
Max. Output Current Ior19.7 mA
Max. output voltage Uor6.5 V
Rigid conductor section0.2 mm² ... 1.5 mm²
Linear Resistance Margin50 Ω ... 500 Ω
Standards/SpecificationsIEC/EN 60079-11
Length to be de-insulated8 mm
Max. Internal Capacity Cidespicable
Maximum Switching Voltage30 V
Maximum safety voltage Um253 V AC
Maximum switching current100 mA
Sizing Insulation Voltage375 VPP
Usable Sensor Types (CTs)B, E, J, K, N, R, S, T, L, U, XK
Flexible conductor section0.2 mm² ... 1.5 mm²
Usable Sensor Types (RTDs)Pt 100, Pt 250, Pt 500, Pt 1000, Pt 2000, Ni 100, Ni 500, Ni 1000, M50, M53, M100
Internal inductance max. Lidespicable
Temperature Measuring Range-200 °C ... 1100 °C (Range depending on sensor type)
Measuring Range, Temperature≥ 51 K (Range depending on sensor type)
Polarity reversal protectionYes
Ambient Temperature (Service)-20 °C ... 70 °C (Individual Equipment: Discretionary Mounting Position)
Electromagnetic compatibilityTesting according to the following standards and requirements: EN 61326-1 for use in the industrial field, NAMUR NE 21
Typical Temperature Coefficient≤ 0.1% (10K)
Intrinsically safe circuits (EPL)Ga
Permissible air humidity (service)≤ 95% (non-condensing)
Flammability class according to UL 94V0
Total permissible line resistance max.50 Ω (per wire, 2-conductor circuit)
Ambient Temperature (Storage/Transport)-40 °C ... 80 °C
I (single electrical circuit): External inductance max. Lor/ Max. external capacity Cor700 mH / 1000 μF
IIA (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor700 mH / 1000 μF
IIB (Single Electrical Circuit): External Inductance Max. Lor/ Max. external capacity Cor330 mH / 570 μF
IIC (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor90 mH / 25 μF

Product Description

Ex i, Temperature converters, Ex i input signals of resistance thermometers in 2, 3 or 4 conductor technology, thermocouples and mV sources are converted to 0 mA / 4 mA non-Ex i signals... 20 mA activ
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top