| Parameter | Value |
|---|---|
| VersionClassificationeClass627-37-16-01eClass7.127-37-16-01eClass827-37-16-01eClass927-37-16-01eClass9.127-37-16-01ETIM5EC001437ETIM6EC001437ETIM7EC001437ETIM8EC001437UNSPSC1539-12-23-26 | |
| EAN | 4011209674493 |
| UPC | 887621408596 |
| ETIM | 5 |
| depth | 79 mm |
| width | 27 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 77 mm |
| ● solid | 1x (1,0 ... 2,5), 2x 1,0, 2x 1,5, 2x 2,5 |
| Group Code | R711 |
| ● at 24 V | 4 A |
| Confirmation | |
| Date5/5/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | LB------ |
| ● at 250 V | 2 A |
| Product Group | 5816 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85364900 |
| Product family | Coupling relays |
| last modified: | 10/13/2021 |
| Net Weight (kg) | 0,114 Kg |
| thermal current | 6 A |
| type of voltage | AC |
| Depth (EF000049) | 77.0 |
| Width (EF000008) | 28.0 |
| fastening method | snap-on mounting |
| Country of origin | Germany |
| Height (EF000040) | 79.0 |
| mounting position | any |
| ● 1 rated value | 50 Hz |
| ● 2 rated value | 60 Hz |
| ● initial value | 0.9 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| switching behavior | monostable |
| ● during storage | -25 ... +70 °C |
| Packaging Dimension | 104,50 x 145,00 x 87,50 |
| Product Description | Plug-in relay complete unit 4 W, 115 V AC LED module red Socket with logic isolation screw terminal 3.5 mm pinning |
| ambient temperature | |
| display version LED | Yes |
| product designation | Coupling relay with plug-in relay |
| protection class IP | IP20 |
| ● during operation | -40 ... +70 °C |
| ● during transport | -25 ... +70 °C |
| ● full-scale value | 1.1 |
| Minimum order quantity | 5 |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AWG cables solid | 1x (18 ... 14), 2x 18, 2x 16, 2x 14 |
| General Product Approval | Declaration of Conformity |
| product type designation | LZS |
| ● at 50 Hz rated value | 115 V |
| ● at 60 Hz rated value | 115 V |
| type of switching contact | Changeover contact |
| Export Control Regulations | AL : N / ECCN : N |
| Nominal current (EF000001) | - |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| control supply voltage at AC | |
| Substance Prohibitance (Date) | 05/01/2012 |
| operating frequency with load | 360 1/h |
| type of electrical connection | screw-type terminals |
| Drive, polarization (EF003355) | Polarized |
| With LED indication (EF005950) | true |
| material of switching contacts | AgNi 90/10 |
| Complete with socket (EF003359) | true |
| control supply voltage frequency | |
| design of the switching function | changeover switch |
| operating frequency without load | 36 000 1/h |
| product component plug-in socket | Yes |
| Type of switch contact (EF003358) | Single contact |
| With detachable clamps (EF003340) | false |
| design of the snap-on socket base | Socket with logic isolation |
| connectable conductor cross-section | |
| product function removable terminal | No |
| Degree of protection (IP) (EF005474) | IP20 |
| Drive, switching attitude (EF003356) | Mono stable |
| Article Number (Market Facing Number) | LZS:PT5B5S15 |
| Voltage type for actuating (EF008242) | AC |
| ampacity of the output relay at DC-13 | |
| Type of electric connection (EF003961) | Screw connection |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With forced-guided contacts (EF003357) | false |
| design of the relay operating mechanism | poled |
| reference code according to IEC 81346-2 | K |
| display version as status display by LED | LED red |
| tightening torque with screw-type terminals | 0.5 ... 0.7 N·m |
| number of CO contacts for auxiliary contacts | 4 |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 0 |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 1x (1.0 ... 1.5), 2x 1.0, 2x 1.5 |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| operational current at DC-13 at 24 V rated value | 4 A |
| design of the switching function positively driven | No |
| mechanical service life (switching cycles) typical | 20 000 000 |
| operational current of auxiliary contacts at AC-15 | |
| operational current of auxiliary contacts at DC-13 | |
| Number of contacts as change-over contact (EF008257) | 4 |
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| Number of contacts as normally open contact (EF008256) | 0 |
| AWG number as coded connectable conductor cross section | |
| percental drop-out voltage related to the input voltage | 30 % |
| Number of contacts as normally closed contact (EF008255) | 0 |
| electrical endurance (switching cycles) at AC-15 at 230 V typical | 250 000 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| supply voltage frequency for auxiliary and control circuit rated value | 50 ... 60 Hz |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| design of the fuse link for short-circuit protection of the auxiliary switch required | fuse gG: 6 A |
| General Product ApprovalDeclaration of ConformityotherConfirmationUK Declaration of ConformityConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide