| Parameter | Value |
|---|---|
| GTIN | 4055626530444 |
| Orderkey | 1716989 |
| (Drawings) | 2 |
| Packing unit | 1 pc |
| Pitch (Drawings) | 7.62 mm |
| Country of origin | PL (Poland) |
| ETIM 5.0 (eCl@ss) | EC002638 |
| ETIM 6.0 (eCl@ss) | EC002638 |
| ETIM 7.0 (eCl@ss) | EC002638 |
| Locking (Drawings) | Latch mechanism/latching at position 4 |
| Custom tariff number | 85366990 |
| (Ambient conditions) | Test passed |
| Minimum order quantity | 25 pc |
| Result (Pull-out test) | Test passed |
| Plug-in system (Drawings) | POWER COMBICON 6 Hybrid |
| Type of contact (Drawings) | Female connector |
| Number of levels (Drawings) | 1 |
| Connection method (Drawings) | Push-in spring connection |
| Range of articles (Drawings) | LPCH 6/..-STL |
| eCl@ss 4.0 (Classifications) | 27260700 |
| eCl@ss 4.1 (Classifications) | 27260700 |
| eCl@ss 5.0 (Classifications) | 27260700 |
| eCl@ss 5.1 (Classifications) | 27260700 |
| eCl@ss 6.0 (Classifications) | 27260700 |
| eCl@ss 7.0 (Classifications) | 27440309 |
| eCl@ss 8.0 (Classifications) | 27440309 |
| eCl@ss 9.0 (Classifications) | 27440309 |
| No. of cycles (Pull-out test) | 25 |
| Specification (Pull-out test) | IEC 60512-15-1:2008-05 |
| Nom. voltage (Item properties) | 1000 V |
| Number of positions (Drawings) | 10 |
| Number of potentials (Drawings) | 10 |
| Dimensional test (Pull-out test) | Test passed IEC 60512-1-2:2002-02 |
| Number of connections (Drawings) | 10 |
| Test result (Ambient conditions) | Test passed |
| Note (Connection capacity signal) | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Cold stress (Durability tests (B)) | -40 °C/2 h |
| Specification (Climatic tests (D)) | IEC 61984:2008-10 |
| Visual examination (Pull-out test) | Test passed IEC 60512-1-1:2002-02 |
| Test force per pos. (Pull-out test) | 20 N |
| (Termination and connection method) | 6 mm² / flexible / > 80 N |
| Brief article description (Drawings) | PCB hybrid connector |
| Specification (Durability tests (B)) | ISO 6988:1985-02 |
| Specification (Mechanical tests (A)) | IEC 60512-9-1:2010-03 |
| Weight per Piece (excluding packing) | 37.600 g |
| Resistance of marking (Pull-out test) | Test passed IEC 60068-2-70:1995-12 |
| Thermal stress (Durability tests (B)) | 100 °C/168 h |
| Corrosive stress (Durability tests (B)) | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Polarization and coding (Pull-out test) | Test passed IEC 60512-13-5:2006-02 |
| Stripping length (Electrical parameters) | 18 mm |
| Pitch (Material data – actuating element) | 7.62 mm |
| Specification (Electrical tests - Function) | IEC 60999-1:1999-11 |
| Contact resistance R1 (Mechanical tests (A)) | 0.42 mΩ |
| Contact resistance R2 (Mechanical tests (A)) | 0.46 mΩ |
| Stripping length (Power connection capacity) | 10 mm |
| Contact material (Connection capacity signal) | Cu alloy |
| Insulating material (Material data - contact) | PA GF |
| Insulating material (Material data - housing) | PA GF |
| Conductor connection test (Ambient conditions) | The stripped-off ends of the largest conductor can be completely inserted in the opening of the terminal point without using excessive force. |
| Type of packaging (Dimensions for the product) | packed in cardboard |
| Pieces per package (Dimensions for the product) | 25 |
| Temperature cycles (Electrical tests - Function) | 192 |
| Dimension a (Material data – actuating element) | 30.48 mm |
| Pull-out test (Termination and connection method) | IEC 60999-1:1999-11 |
| Width [ w ] (Material data – actuating element) | 51.73 mm |
| Height [ h ] (Material data – actuating element) | 35.65 mm |
| Insertion/withdrawal cycles (Mechanical tests (A)) | 25 |
| Length [ l ] (Material data – actuating element) | 48 mm |
| Withdraw strength per pos. approx. (Pull-out test) | 4 N |
| Insertion strength per pos. approx. (Pull-out test) | 7 N |
| Insulating material group (Material data - contact) | I |
| CTI according to IEC 60112 (Material data - contact) | 600 |
| CTI according to IEC 60112 (Material data - housing) | 600 |
| Surface characteristics (Connection capacity signal) | Tin-plated |
| Conductor cross section solid (Electrical parameters) | 0.75 mm² ... 10 mm² |
| Specification (Air clearances and creepage distances) | IEC 60999-1:1999-11 |
| Ambient temperature (assembly) (Packaging information) | -5 °C ... 100 °C |
| Specification (Mechanical tests according to standard) | IEC 60664-1:2007-04 |
| Ambient temperature (operation) (Packaging information) | -40 °C ... 100 °C (dependent on the derating curve) |
| Denomination packing units (Dimensions for the product) | Pcs. |
| Withdraw strength per pos. approx. (Temperature cycles) | 4 N |
| Conductor cross section flexible (Electrical parameters) | 0.75 mm² ... 6 mm² |
| Insertion strength per pos. approx. (Temperature cycles) | 7 N |
| Power-frequency withstand voltage (Durability tests (B)) | 3.31 kV |
| Power-frequency withstand voltage (Mechanical tests (A)) | 3.31 kV |
| Conductor cross section solid (Power connection capacity) | 0.2 mm² ... 1.5 mm² |
| Cylindrical gauge a x b / diameter (Electrical parameters) | 4.3 mm x 4.0 mm / 4.0 mm |
| Result, degree of protection, IP code (Climatic tests (D)) | Back of hand safety with IP10 access probe |
| Conductor cross section AWG / kcmil (Electrical parameters) | 18 ... 8 |
| Conductor cross section flexible (Power connection capacity) | 0.2 mm² ... 1.5 mm² |
| Impulse withstand voltage at sea level (Durability tests (B)) | 7.3 kV |
| Impulse withstand voltage at sea level (Mechanical tests (A)) | 7.3 kV |
| Test for conductor damage and slackening (Ambient conditions) | IEC 60999-1:1999-11 |
| Test – repeated connection and release (Ambient conditions) | IEC 60999-1:1999-11 |
| Cylindrical gauge a x b / diameter (Power connection capacity) | 2.4 mm x 1.5 mm / 1.5 mm |
| Ambient temperature (storage/transport) (Packaging information) | -40 °C ... 70 °C |
| Conductor cross section AWG / kcmil (Power connection capacity) | 24 ... 16 |
| Contact holder in insert requirements >20 N (Temperature cycles) | Test passed |
| Flammability rating according to UL 94 (Material data - contact) | V0 |
| Flammability rating according to UL 94 (Material data - housing) | V0 |
| Polarization when inserted requirement >20 N (Temperature cycles) | Test passed |
| Test current (maximum cross section) (Electrical tests - Function) | 41 A DC |
| Test current (minimum cross section) (Electrical tests - Function) | 9 A DC |
| Insulation resistance, neighboring positions (Mechanical tests (A)) | |
| Metal surface contact area (top layer) (Connection capacity signal) | Tin (4 - 8 µm Sn) |
| Rated surge voltage (II/2) (Mechanical tests according to standard) | 6 kV |
| Rated surge voltage (III/2) (Mechanical tests according to standard) | 8 kV |
| Rated surge voltage (III/3) (Mechanical tests according to standard) | 8 kV |
| Metal surface terminal point (top layer) (Connection capacity signal) | Tin (4 - 8 µm Sn) |
| Rated insulation voltage (II/2) (Mechanical tests according to standard) | 1000 V |
| Rated insulation voltage (III/2) (Mechanical tests according to standard) | 1000 V |
| Rated insulation voltage (III/3) (Mechanical tests according to standard) | 800 V |
| Clearances and creepage distances (Mechanical tests according to standard) | IEC 60664-1:2007-04 |
| Minimum creepage distance value (II/2) (Mechanical tests according to standard) | 5 mm |
| Minimum creepage distance value (III/2) (Mechanical tests according to standard) | 5 mm |
| Minimum creepage distance value (III/3) (Mechanical tests according to standard) | 10 mm |
| Minimum clearance - inhomogeneous field (II/2) (Mechanical tests according to standard) | 5.5 mm |
| Minimum clearance - inhomogeneous field (III/2) (Mechanical tests according to standard) | 8 mm |
| Minimum clearance - inhomogeneous field (III/3) (Mechanical tests according to standard) | 8 mm |
| Conductor cross section / conductor type / tensile force (Termination and connection method) | 0.75 mm² / solid / > 30 N |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical parameters) | 0.75 mm² ... 6 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Electrical parameters) | 0.75 mm² ... 6 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Power connection capacity) | 0.25 mm² ... 1 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Power connection capacity) | 0.25 mm² ... 1.5 mm² |
Technical specifications and performance data