| Parameter | Value |
|---|---|
| 0.75 mm² / flexible / > 30 N | |
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Pitch | 10.16 mm |
| Result | Test passed |
| Amplitude | 0.15 mm (10 Hz ... 60.1 Hz) |
| Frequency | 10 - 150 - 10 Hz |
| Width [w] | 33.68 mm |
| Height [h] | 32.2 mm |
| Length [l] | 56.3 mm |
| Sweep speed | 1 octave/min |
| Locking type | without |
| Product line | COMBICON Connectors XL |
| Product type | PCB connector |
| No. of cycles | 25 |
| Specification | IEC 60999-1:1999-11 |
| Number of rows | 1 |
| Product family | LPC 16 HC/..-ST |
| Thermal stress | 105 °C/168 h |
| Color (Housing) | green (6021) |
| Mounting flange | without |
| Connector system | COMBICON PC 16 advanced |
| Contact material | Cu alloy |
| Corrosive stress | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Stripping length | 18 mm |
| Connection method | Lever Push-in connection |
| Type of packaging | packed in cardboard |
| Contact resistance | 0.235 mΩ |
| Nominal current IN | 76 A |
| Nominal voltage UN | 1000 V |
| Notes on operation | In accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load. |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Insulating material | PA |
| Number of positions | 3 |
| Rated voltage (II/2) | 1000 V |
| Contact resistance R1 | 0.235 mΩ |
| Contact resistance R2 | 0.212 mΩ |
| Nominal cross section | 16 mm² |
| Rated voltage (III/2) | 1000 V |
| Rated voltage (III/3) | 1000 V |
| Test duration per axis | 2.5 h |
| Contact connection type | Socket |
| Surface characteristics | hot-dip tin-plated |
| Color (Actuating element) | orange (2003) |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Rated surge voltage (II/2) | 6 kV |
| Tested number of positions | 6 |
| Conductor cross section AWG | 18 ... 4 |
| Insertion/withdrawal cycles | 25 |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (III/3) | 8 kV |
| Conductor cross section rigid | 0.75 mm² ... 16 mm² |
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 105 °C (dependent on the derating curve) |
| Rated insulation voltage (II/2) | 1000 V |
| Conductor cross section flexible | 0.75 mm² ... 16 mm² |
| Rated insulation voltage (III/2) | 1000 V |
| Rated insulation voltage (III/3) | 1000 V |
| minimum creepage distance (II/2) | 5.5 mm |
| Power-frequency withstand voltage | 4.26 kV |
| minimum creepage distance (III/2) | 8 mm |
| minimum creepage distance (III/3) | 12.5 mm |
| Conductor/PCB connection direction | 0 ° |
| Cylindrical gauge a x b / diameter | - / 5.4 mm |
| Withdraw strength per pos. approx. | 6 N |
| Insertion strength per pos. approx. | 8 N |
| Relative humidity (storage/transport) | 30 % ... 70 % |
| Flammability rating according to UL 94 | V0 |
| Impulse withstand voltage at sea level | 9.8 kV |
| Metal surface contact area (top layer) | Tin (10 - 16 µm Sn) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Metal surface terminal point (top layer) | Tin (10 - 16 µm Sn) |
| Insulation resistance, neighboring positions | > 5 MΩ |
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.75 mm² ... 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.75 mm² ... 16 mm² |
| Conductor cross section/conductor type/tractive force setpoint/actual value | 0.75 mm² / solid / > 30 N |
Technical specifications and performance data
Installation and operation guide