| Parameter | Value |
|---|---|
| PL | and |
| CFF | 80% |
| SIL | Three |
| PFHd | 1,40 E-08 |
| Type | Four |
| Dcavg | 98,60% |
| MTTFd | One hundred |
| SLICL | Three |
| Moisture | 95% (non-condensing) |
| Dimensions | 50mm (front) x 60mm |
| Connections | M12-5-pole (emitter)M23-19-pin (receiver)2 x M12-5 poles (Muting) |
| Output type | 2 x PNP-NA (safety output OSSD) |
| Load current | 500mA |
| Nominal range | ≤ 16m |
| Certifications | CE, cULus, TÜV |
| Supply voltage | 19,2 ... 28,8 Vdc |
| Load capacitive | ≥ 2 µF |
| Number of beams | Forty five |
| Protected height | 1360mm |
| Functions available | Manual reset/automatic, EDM, status barrier, Muting 4 sensors |
| Shock and vibration | According to the standard IEC 61496-1 |
| Storage temperature | -25°C...+70°C |
| Accessories included | ST 202, ST 203 |
| Degree of protection | IP65 |
| Angle of opening cash | ≤ ±2,5° |
| Operating temperature | 0°C...+55°C |
| Power input - receiver | 6W |
| Principle of operation | Transmitter + receiver |
| Sensitivity adjustment | 23ms |
| Delay to the availability | 15s |
| Immunity to ambient light | According to the standard IEC 61496-2 |
| Resistive load equivalent | ≥ 48 Ω |
| Power consumption - emitter | 3W |
| Length cables (power/output) | 100m |
| Electromagnetic compatibility | According to directive 2014/30/EU |
Technical specifications and performance data
Installation and operation guide