| Parameter | Value |
|---|---|
| Step | 13 mm |
| Width [w] | 40.2 mm |
| Height [h] | 39.4 mm |
| Length [l] | 48.2 mm |
| Peel Length | 18 mm |
| Product Line | COMBICON Terminals Special |
| Product Type | Condenser terminal block |
| Overall Height | 39.4 mm |
| Product Family | LLH 25/.. -H |
| Color (Housing) | Black (9005) |
| Connection type | Push lock spring connection |
| Number of poles | 3 |
| Contact material | Cu Alloy |
| Dimension Scheme | |
| Type of mounting | Direct plug-in connection technology |
| Nominal Current IN | 90 A |
| Nominal voltage UN | 1000 V |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Degree of pollution | 3 |
| Insulating material | PA |
| Number of potentials | 3 |
| Color (Drive Element) | Orange (2003) |
| Number of connections | 3 |
| Nominal voltage (II/2) | 1000 V |
| Sizing voltage (III/3) | 1000 V |
| Surface Characteristics | Malleable cast iron tinning |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Male gauge a x b / Diameter | - / 5.4 mm |
| Dimensioning voltage (III/2) | 1000 V |
| Ambient Temperature (Service) | -40 °C ... 100 °C (depending on the rating curve) |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Nominal transient voltage (II/2) | 6 kV |
| Sizing Insulation Voltage (II/2) | 1000 V |
| Nominal transient voltage (III/2) | 8 kV |
| Nominal transient voltage (III/3) | 8 kV |
| Sizing Insulation Voltage (III/2) | 1000 V |
| Sizing Insulation Voltage (III/3) | 1000 V |
| Minimum creepage line value (II/2) | 5.5 mm |
| Minimum creepage line value (III/2) | 8 mm |
| Minimum creepage line value (III/3) | 12.5 mm |
| Dimensioning transient voltage (II/2) | 6 kV |
| Flammability class according to UL 94 | V0 |
| Dimensioning Transient Voltage (III/2) | 8 kV |
| Dimensioning transient voltage (III/3) | 8 kV |
| Metal surface contact area (top layer) | Tin (4 - 8 μm Sn) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Metal surface of the terminal point (top layer) | Tin (4 - 8 μm Sn) |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ball hardness test temperature according to EN 60695-10-2 | 125 °C |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Flexible conductor section with toe cap, with plastic sleeve | 2.5 mm² ... 25 mm² |
| Flexible conductor section with toe cap, without plastic sleeve | 2.5 mm² ... 25 mm² |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 5.5 mm |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 8 mm |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 8 mm |
| Flammability number of GWFI incandescent filaments according to EN 60695-2-12 | 850 |
| Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13 | 775 |
Technical specifications and performance data