| Parameter | Value |
|---|---|
| • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. | |
| Type | Straight, plastic molded |
| Voltage | 630 V |
| Shielded | yes |
| Cable type | PSLC11Y-J |
| No. of pos. | 5+PE |
| Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Thread type | M17 |
| Acceleration | 5 m/s² |
| Cable length | 2 m |
| Halogen-free | in accordance with EN 50267-2-1 |
| Max. current | 14 A |
| Product type | Signal and power cable |
| Test voltage | 4 kV |
| UL AWM style | 80°C/1000 V |
| Cable structure | 4x 1.0 mm² + 2x 0.5 mm² |
| Traversing path | 5 m |
| Type of locking | Screw locking mechanism |
| Article revision | 11 |
| Flame resistance | according to UL 758/1581 FT1 |
| Housing material | Zinc die-cast |
| Resistance to oil | EN 60811-2-1 |
| Contact resistance | < 0.3 mΩ |
| Notes on operation | Observe derating curve. |
| Single wire, color | black 1, black 2, black 3, black 4, green/yellow Power wires + PE |
| Special properties | Flexible cable conduit capable |
| Degree of pollution | 3 |
| Max. bending cycles | 5000000 |
| Rated surge voltage | 6 kV |
| Degree of protection | IP67, when in locked state |
| Overvoltage category | III |
| Direction of rotation | Standard |
| Contact switching type | Socket |
| Nominal voltage, cable | 1000 V |
| Outer sheath, material | PUR |
| External cable diameter | 8.90 mm ±0.3 mm |
| Material wire insulation | PP |
| Insertion/withdrawal cycles | 50 |
| Ambient temperature (operation) | -40 °C ... 105 °C |
| Smallest bending radius, movable installation | 69 mm |
| Ambient temperature (operation) for fixed installation | -40 °C ... 80 °C |
| Ambient temperature (operation) for flexible installation | -25 °C ... 80 °C |
Technical specifications and performance data
Installation and operation guide