Key Specifications
GTIN:4055626633879
Orderkey:1045379
(Drawings):
Catalog page:Page 213 (C-4-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626633879
Orderkey1045379
(Drawings)
Catalog pagePage 213 (C-4-2019)
Packing unit1
Number (General)1
(EMC Directives)EN 61000-6-3
ETIM 6.0 (eCl@ss)EC002300
ETIM 7.0 (eCl@ss)EC002300
Interface (General)Ethernet
Operation (General)via Proficloud application and web interface
Custom tariff number85437090
Pictogram (Drawings)
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Sampling rate (General)500 kHz
Block diagram (Drawings)
Basic functions (General)Acquisition of sensor data
Type (Ambient conditions)DIN rail module, one-piece
Color (Ambient conditions)traffic grey A RAL 7042
Screw thread (Connections)M3
Connection method (General)RJ45
Horizontal pitch (Drawings)1.3 Div.
Operating current (General)≤ 70 mA
Operating voltage (General)24 V DC (-15% ... +20% including all tolerances and ripple)
Transmission speed (General)10/100 Mbps
eCl@ss 9.0 (Classifications)27200316
Connection name (Connections)SPD remote indication contact monitoring
Note (Typical characteristics)The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
Stripping length (Connections)8 mm
Connection method (Connections)Screw terminal block
Maximum measuring period (General)1 s
Mounting type (Ambient conditions)DIN rail: 35 mm
Cloud platform (Ambient conditions)Proficloud
Housing material (Ambient conditions)Polyamide
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Screw thread (Typical characteristics)M3
Note on the connection method (General)pluggable
Connection name (Typical characteristics)24 V supply
Standards/specifications (EMC Directives)EN 61000-6-2
Immunity to EF (Remote indication contact)Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Stripping length (Typical characteristics)8 mm
Connection method (Typical characteristics)Screw terminal block
Immunity to ESD (Remote indication contact)Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Tightening torque (Typical characteristics)0.5 Nm ... 0.6 Nm
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Immunity to burst (Remote indication contact)Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2.2 kV
Immunity to surge (Remote indication contact)Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1 kV
Permissible humidity (operation) (Dimensions)30 % ... 95 % (non-condensing)
Supports cloud computing (Ambient conditions)yes
Detectable values (current strength) (General)100 A ... 40 kA
Number of connections (Typical characteristics)4
Interference emission (Remote indication contact)Noise immunity test in accordance with EN 61000-6-2 Noise emission EN 61000-6-3/IEC 61000-6-3 Class B
Ambient temperature (storage/transport) (Dimensions)-35 °C ... 85 °C
Permissible humidity (storage/transport) (Dimensions)30 % ... 95 % (non-condensing)
Electromagnetic compatibility (Remote indication contact)Conformance with EMC Directive 2014/30/EU
Immunity to conducted interference (Remote indication contact)Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V

Product Description

Evaluation unit for recording transient currents and transient overvoltages using external sensor cables. Communication of measurement data via Ethernet to PROFICLOUD. The data evaluated in the cloud
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top